78 PROGRAMMING THE SYSTEM
- D. RF OPTIONS -
I
III
COMMENTS: Enter 1 if first 4260 is installed. Enter 0 if no 4280 is
installed.
FIRST 4260
RF EXPANDER SELECT
(011)
SECOND 4260
RF EXPANDER SELECT
(O/l 1
RF TRANSMITTER
LOW BATTERY
ANNUNCIATION ENABLE
(O/l 1
RF .TRANSMllTER
LOW BATTERY
REPORT ENABLE
(O/l 1
4260 CHECK-IN
INTERVAL
(02-15 or 00 for no check-in)
RF TRANSMITTER
CHECK-IN INTERVAL
(02-15 or 00 for no check-in)
1’26
1’27
1’26
1’29
1’30
1.31
I
I
COMMENTS: Enter 1 if 2nd 4260 is installed. Enter 0 if only one or
no 4260 is installed.
IMPORTANT!: If
second 4260 is installed, cut Blue jumper on 2nd
4260.
I
I
COMMENTS: Enter 0 if audible beep and display annunciation upon
RF transmitter low battery condition is desired only in disarmed state.
Enter
1
if audible beep and display is desired in both armed and
disarmed states.
I
El
COMMENTS: Enter
1
if a trouble message for RF transmitter low
battery conditions is to be sent to the central station. Enter 0 if no
report for transmitter low battery is desired. Note that a trouble
message will be sent for a transmitter supervision failure independent
of this selection.
1 1 I
lolsl
COMMENTS: Enter the check-in monitoring interval in a-hour
increments; enter 02-15 (4-30 hours). Failure of a receiver to
receive any RF signal within the time entered will result in activation of
the response type programmed for zone 90 for the first 4260 (4260-
6)-and zone 66
for
the second 4260 and their related communication
reports.
NOTES: If a zero is programmed; super-&ion of the RF receiver will
be disabled (response types for zones 66 and 90 are disabled).
1
I [
ll
COMMENTS:
Enter the check-in monitoring interval in P-hour
increments; enter 02-15 (4-30 hours). Failure of an individual
transmitter to send a supervision signal within the time entered will
result in a trouble response and related communication report.
NOTES: If a zero is programmed, this feature is disabled.
ADRbK!O’s VISTA Xbf SERIES TECHNICAL REFERENCE MANUAL