72
PROGRAMMING TEE SYSTEM
.--.
PROGRAMMING STEPS
1. Enter ProgrammIng mode Programming mode can be entered in one of two ways.
1) By depressing the r] and [#I keys at the same time within 30 seconds after
power is applied to
me
Control.
2) By keying the installer code, followed by depression of CODE + 0 + 0 keys.
The factory installer wde can be changed once in the program mode.
Immediately following entry into the program mode, the following will be
displayed on a 513OXMf5137:
Program Mode
l
Flfl#Visw- 09
The 413OXMI4137 consoles dispfay: 00
Following the above display, the system is ready to be programmed for the
communication format parameters, or accept entries for the first address (00).
2. Sat Standard Defaults Once the Programming mode is entered, clear the system’s memory by
pressing 37. This ensures ail program fields are set to their factory set, pre-
programmed values.
3. Set Communlcatlon
Format Defaults
(If deslred)
If the system is to be connected to a central station via telephone line, the
appropriate communication format settings should be programmed now.
VISTA provides four sets of preprogrammed communication formats, which,
lf used, fill all appropriate fields with preset values (see SUMMARY OF
CONNECTIONS section for Tit of values). These values can be modiii later
as desired. To pre-program a particular communication format, use the
following chart:
~~~~~~
IMPORTANTl:
Pre-programming of one of these formats must be
performed bet&i3 any other field entries are made.
4. Program the data flelds
To program the first set of fiilds (fields 00-90). simply press the r] key plus
the P-digit field address (for example, press ‘01 for field ‘01). then make the
required entry. To program the sewed set of fields (fields l*OO-1’49). press
l
94, and note that the alpha consoles display the words ALT PROGRAM
MODE, and the 413OXMI4137 consoles display the word CHECK. Once the
console indicates that it has accessed the second set of addresses, simply
press the r] key plus the P-digit field address (ex. ‘01 for field 1’01) and
make the required entry. To return to the first set of fiilds, press ‘99.
When a data field has been wnpletely programmed, the console WI %eep.
three times and then automatically display the next data field address in
numerical order. lf the number of digits that you enter ln the data fiilcl Is less
than the maximum pennltted (for example, phone number), the console
displays the fast entry and watts. To proceed, the next data field address to
be programmed must be entered manually (for example, press ‘05).
To review the contents of a data field, key # prus address (for example #05).
me fielcfs entries will be diifayed, but no changes can be made.
.
1
5. In case of errors
If an address is improperty entered, the console will display FC . If a program
entry is improperly entered (for example, a larger number than that whii is
permitted), the console display will go blank. In either case, simply m-enter
the correcf number.
ADEMCO’s VISTA XM SERIES TECHNICAL RRFERENCE MANUAL
WWW.DIYALARMFORUM.COM
Kommentare zu diesen Handbüchern