- 0.
PASSIVE INFRARED MOTION DETECTORS -
GENERAL
INFORMATION
POLLING LOOP
(4196)
SYSTEM CONFIGURATION (PERIPHERALS)
4 3
Select a mounting site with the following notes in mind: Best coverage will be
obtained if the mounting site is selected such that the likely direction of
intruder motion is across the pattern of protection.
Avoid locating the unit where central heating radiators, flames or heating
outlet ducts are within the protective zones.
Avoid locating the unit in direct sunlight or directly above strong sources of
heat.
Avoid locating the unit on unstable surfaces.
Avoid running alarm wiring close to heavy duty electrical cables.
Make wire connections as shown:
PIR
The 4196 is a quad element passive infrared detector with a buitl-in RPM that
is connected directly to the- polling loop. It provides up to 40 feet of
protection, using a wide angle mirror, or up to 70 feet of corridor protection
using the long range mirror (both mirrors are provided with the unit). A right
zone is available for use with closed-circuit devices and can be programmed
for a different zone type than the PIR. The 4196 can be flat wall mounted or
comer mounted, using the mounting plate provided. Programming of the
unit’s address ID is accomplished via the units DIP switches (see Table 1 in
the preceding section). Refer to the instructions accompanying the 4196 for
patterns of coverage and procedures for changing mirrors.
4196 PIR W/BUILT-IN RPM
LiiFEl
WIDE ANGLE LONG RANGE
MIRROR
MIRROR
(SET FOR ID NO. 8)
THIS RIGHT LOOP IS ALWAYS
NORMALLY CLOSED, UNSUPERVISED!
DO NOT USE EOLR!
Diagram 24. 4196 POLLING LOOP PIR
ADEbfCO’s VISTA XM SERIES TECtjlNICAL REFERENCE MANUAL
WWW.DIYALARMFORUM.COM