ADEMCO Vista-128FB Einstellungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 147
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
Section 3 - Installing the Control
3-5
Using a Siren Driver
To install a siren driver, perform the following steps:
Step Action
1 Mount the siren driver in the panel’s
cabinet.
2 Wire the siren driver to the control and to
the speaker(s). (See the driver’s
instructions.)
3 Cut the blue jumper on the upper left-hand
corner of the panel’s PC board.
4 Program Zone 970 with no response type
(00).
Disabling the Supervision of the Alarm Output
To install the alarm output and disable the supervision
feature, perform the following steps:
Step Action
1 Wire the devices to terminals 4 and 5,
observing polarity if necessary.
2 Cut the blue jumper on the upper left-hand
corner of the panel’s PC board.
3 Program Zone 970 with no response type
(00).
Telephone Line Connections
Connect the main dialer output to telephone company
lines using the RJ31X cables supplied.
U
L
The telephone line inputs have overvoltage
protection in accordance with UL1459, as
specified in UL985/UL1023.
The system is shipped defaulted for Contact ID
format. It is the only format capable of uniquely
reporting all 250 zones, as well as openings
and closings for all 250 users. This requires
central stations to be equipped with the
ADEMCO 685 receiver using software level
4.10 or higher. If you need an update, contact
your distributor.
To prevent the risk of shock, disconnect
phone lines at the telco jack before servicing.
If the communicator is connected to a PABX,
be sure it has a backup power supply that
can support the PABX for 24 hours (central
station) or 60 hours (remote station). Many
PABXs are
not
power-backed up, and this
can result in a communication failure if power
is lost
.
Reporting Formats
The system supports the following formats:
ADEMCO Low Speed 3+1; 4+1; 4+2; Sescoa/Radionics
3+1; 4+1; 4+2; ADEMCO 4+2 Express; ADEMCO High
Speed; ADEMCO Contact ID
TERMINALS
ON CONTROL
EARTH GROUND
INCOMING TELCO LINE
Handset
TIP
RING
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
TIP
RING
GROUND
PREMISES
PHONES
{
{
BROWN (TIP)
GREY (RING)
GREEN (TIP)
RED (RING)
26 27 28 29 30
Incoming
Telco Line
Figure 3-8: Telephone Line Connections
Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9
Seitenansicht 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 146 147

Kommentare zu diesen Handbüchern

Keine Kommentare