VISTA-128BP/VISTA-250BP Installation and Setup Guide
3-18
3 Connect the module to the control’s keypad
terminals (6, 7, 8, and 9).
00000
ECP Bus
Dip Switch
Optional
Keyswitch
Connection
SIDE
VIEW
All Switches shown
in Up position.
(ECP Address 23)
Terminal
Block
Connect to
Keypad
Terminals
Figure 3-23: Wiring the FSA Module
Installing 4101SN Relay Modules
The 4101SN V-Plex Single Output Relay Module is a
serial number polling loop output device. The 4101SN
features the following:
Form C relay contacts rated at 2A, 28VAC/VDC
with contact supervision.
The position of the relay is supervised, but not
the actual external contact wiring.
One class B/style B EOLR-supervised auxiliary
input zone.
Operating power and communication with control
panels via the V-Plex polling loop.
Electronics mounted in a small plastic case with
tamper-protected cover.
Connect the device to the polling loop, terminals 24 (+)
and 25 (-). Be sure to observe polarity
Installing X10 Devices
X-10 devices are either plugged into standard AC
outlets or wired into the AC electrical system by a
licensed electrician, depending on the type of device
used.
Note each devices House and Unit Code
setup, as these codes will be used to program
the devices in
Output Programming
in
#93
Menu Mode
described in the
Programming
Guide
.
X-10 devices require the use of a 1361X10 transformer
in place of the regular 1361 transformer.
X-10 devices respond to “on” and “off” commands sent
from the panel through the 1361X10 transformer.
To connect the 1361X10 transformer, see Connecting
the Transformer, later in this section.
Installing the Ground Start Module
U
L
The Ground Start Module is not intended for
use in UL Listed applications.
Output 1 may be used to trigger an optional 675
Ground Start Module for installations having
telephone lines that require ground start instead of
loop start operation to obtain a dial tone from the telco
central office.
When the panel has a message to transmit to the
central station, it seizes the line, goes off hook, and
then triggers the 675 Module to connect the RING side
of the telephone line to earth ground. The panel
causes the module to break the connection between
RING and earth ground when it obtains a dial tone.
You cannot use Output 1 for the Ground Start
if you are using it for a Smoke Detector Reset
or an AAV module.
To install the 675 Ground Start Module, perform the
following steps:
Step Action
1 Determine which side of the telephone line
is the RING side by connecting the (+) lead
of a DC voltmeter to earth ground, and the
(-) lead to one side of the telephone line.
The wire that reads + 50VDC is the
RING side.
2 Connect the 675 Ground Start Module to
the panel’s J7 connector trigger output 1,
to auxiliary power, and to the RING side of
the telephone line as shown in Figure 3-24.