Section 3 - Installing the Control
3-27
The VGM then reformats and retransmits this
information to the Main Logic Board, (MLB) on the
PassPoint ACS network bus.
U
L
Interfacing the VISTA-128BP/VISTA-250BP
with the PassPoint Access Control System via
the VISTA Gateway Module is not permissible
for UL installations.
Wiring the VISTA Gateway Module
The VISTA Gateway Module is connected between the
ECP bus (VISTA-128BP/VISTA-250BP keypad
terminals) and the network bus of the PassPoint
Access Control System. See Figure 3-32 for the proper
wiring connections.
}
ECHELON NETWORK
(PASSPOINT ACS)
YELLOW
RED
BLACK
PROM C
TRANSFORMER
4-PIN
KEYPAD
PLUG
}
TO
CONTROLS
KEYPAD
TERMINALS
GREEN
Figure 3-32: Wiring the VISTA Gateway Module
Installing a 4100SM
The 4100SM is used to print event log reports to a
serial printer or to interface the control with a
computer equipped with Home Automation software.
When using the 4100SM, the system can
interface with either a serial printer or Home
Automation. It cannot do both.
NOTE: See SECTION 4: Programming for the
programming details when using the 4100SM.
Printer/Computer Configurations
Configure the serial printer or the Home Automation
computer as follows:
8 data bits, no parity, 1 stop bit
1200 baud
Connecting the 4100SM to a Serial Printer
To connect a serial printer using the 4100SM, refer to
Figure 3-33and perform the following steps:
Step
Action
1
Connect terminal 1 on the 4100SM to the
Violet wire on the 4142TR cable.
2
Connect terminal 6 on the 4100SM to the
Brown wire on the 4142TR cable.
3
Connect the 4142TR cable to J8 on the
control.
4
Connect terminals 8 and 7 of the 4100SM to
terminals 6 and 7 (aux. power (+) and (-)),
respectively of the control.
5
Connect the UL EDP Listed serial printer to
the 4100SM Interface Module.
The 4100SM Module is supplied with a 10-
foot RS232 cable. A longer cable can be used
if the VISTA-128BP/VISTA-250BP is
separated from the serial printer by more
than 10 feet, but the total cable length
should be less than 50 feet.
123456789
NU
J8 CONNECTOR
VIOLET
GREY
YELLOW
RED
GREEN
BROWN
BLUE
BLACK
IN
2
IN
3
G
R
O
U
N
D
O
U
T
5
O
U
T
6
G
R
O
U
N
D
G
R
O
U
N
D
PRINTER DTR
4142TR CABLE (SUPPLIED WITH 4100SM)
8
7
6
5
4
3
2
1
4100SM SERIAL MODULE
+ PWR
- (GND)
RXD
not used
not used
TXD
not used
DTR
BLUE WHITE
To TB6 Aux. Power (+)
(25mA current draw)
To TB7 Aux. Power (-)
USE GENDER CHANGER
SUPPLIED WITH 4100SM
IF PRINTER HAS DB25
MALE CONNECTOR
3M
Cable
Supplied with
4100SM
SERIAL PRINTER
SET FOR: 8 DATA BITS
EVEN PARITY
STOP BIT
300/1200 BAUD
4100SM JUMPERS
(CUT TO SET RESPECTIVE SIGNAL FLOATING)
COLOR FUNCTION PIN #
RED
BLUE
WHITE
CD
CTS
DSR
8
5
6
RED
4100SM-011-V0
Figure 3-33: 4100SM Using a Serial Printer
NOTE: See the 4100SM Installation Instructions for
details concerning the serial printer operation.
Connecting the 4100SM to a Home Automation
Computer
To connect the computer to the 4100SM, refer to
Figure 3-34 and perform the following steps:
Step
Action
1
Connect terminal 23 on the control panel to
terminal 3 on the 4100SM.
2
Connect terminal 6 on the 4100SM to the
Brown wire on the 4142TR cable.
3
Connect the 4142TR cable to J8 on the
control.
4
Connect terminals 8 and 7 of the 4100SM to
terminals 6 and 7 (aux. power (+) and (-)),
respectively of the control.
5
Connect the Home Automation computer