VISTA-128BP/VISTA-250BP Installation and Setup Guide
2-4
Press [] + [0] or [] + [9] to return to the master
partition. Otherwise, if no keys are pressed for 2
minutes, the system automatically returns to the
master partition
The sounder on a Master keypad reflects the sound of
the most critical condition on all of the partitions. The
priority of the sounds, from most to least critical, is as
follows:
1. Pulsing fire alarm sounds
2. Steady burglar alarm sounds
3. Trouble sounds (rapid beeping)
Silence the sounder by pressing any key on the Master
keypad or a keypad on the partition where the
condition exists.
A Master keypad uses the same panics as
Partition 1. Master keypad panics are sent to
Partition 1, and will activate on Partition 1.
Therefore, panics must be programmed for
Partition 1.
Panel Linking
Up to eight VISTA-128BP/VISTA-250BP control panels
may be networked, enabling a user to control the
features of all control panels from a single location.
The panel linking bus supports an end-to-end network
length of up to 4,000 feet. This makes it ideal for
multi-building environments (e.g., shopping mall,
college campus, etc.).
U
L
Panel Linking is not permitted in UL
installations.
Panel linking requires a VA8200 Panel Link Module
(PLM) on each VISTA-128BP/VISTA-250BP. Users can
link (access other control panels) in any of three
different modes: Single-Partition, Single-Panel Mode;
Multi-Partition, Multi-Panel Mode; Multi-Panel View
Mode. These modes are described later in this section.
Each PLM connects to the ECP bus on the control
panel and communicates to each PLM via an RS-485
bus (3-wire twisted cable run) with a maximum wire-
run of 4000 feet end-to-end.
Users 001-050 are the only users that can
perform panel linking and are automatically
assigned panel linking access when added
to the system.
An alpha keypad must be used for panel
linking.
The system may take up to 7 seconds to
respond to a command when in a panel
linking mode
NOTE: A user cannot access partitions or panels that
they have not been assigned to.
Panel Link Module Supervision
The Panel Link Module can be supervised for its
connection to the control panel. The module’s
supervisory zone is zone 8xx, where “xx” = the ECP
address of the PLM. You must program that zone with
response type 05 (Day/Night) in Zone Programming in
the #93 Menu Mode (refer to the Programming Guide
for detailed programming instructions). If you want to
report the supervisory failure to the central station
and/or to a paging service, the appropriate reporting
parameters for that zone must be programmed.
If you want the supervisory failure of PLM(s) on other
linked control panels to display on this control panel,
they must be programmed into Zone Programming in
the #93 Menu Mode with response type 14 in this
control panel (refer to the Programming Guide for
detailed programming instructions). The panel ID
number for each module must match the panel ID
number programmed in Device Programming of its
“host” VISTA-128BP/VISTA-250BP.
How to Use Panel Linking
Panel Linking can be used in any of three different
modes:
Single-Partition, Single-Panel displays status of
a partition on a remote control panel and allows
control of that remote control panel.
Multi-Partition, Multi-Panel Mode displays
status and allows arming/disarming of multiple
partitions at once on a remote control panel.
Multi-Panel View Mode displays status and
allows arming/disarming of multiple remote
control panels at a time.
NOTE: A user will not be able to access or view
partitions or panels that they have not been assigned
to.