38
Group 7 — Option 8 Downloader Options
This option determines under what set conditions the Ademco Microtech Downloader
software may access the Accord xpC panel. There are three options:
0. Full Access.
1. No Access When Set.
2. No Unsetting.
This option defaults to 1 (No access when set).
Full Access (0), permits access at any time and the Downloader software can perform
all system operations.
No Access When Set (1), prevents access in any (Full, Part or Night) set condition.
The system must first be unset from the site, before the Downloader software can
perform all system operations.
No Unsetting (2), permits access the system to perform a download at any time.
However, the Downloader cannot unset the system from a set condition.
Group 7 — Option 9 Zone Auto Omit
This option determines the number of times a zone can activate during a set period
before it is omitted from the system. There are two options:
0. Two activations during a set period then the zone is omitted.
1. One activation during a set period then the zone is omitted.
This option defaults to 0 (Two activations).