Section 3: Programming the Accord XPC
Important: The following programming instructions integrate programming details
using both LED and Icon keypads. Icon keypad (in brackets) follow
LED keypad indications.
An Introduction to Programming the Accord xpC
Getting In and Out of Programming Mode Using LED and Icon keypads.
All zone and system programming must be carried out from the Programming Mode. To
enter Programming Mode enter the Engineer Code, press the # key and then the Ö key.
The Engineer Code is 9090 by default.
The keypad beeps twice, the Day LED () goes out and the Power LED ( ) on the
keypad flashes to indicate that the system is in programming mode.
To exit Programming Mode press the # key followed by the Ö key. The power LED ( )
on the keypad stops flashing and the Day LED () activates.
During engineer programming mode, no communication to the central station will
take place. To perform an engineer reset enter the four digit engineer code (no need to
enter programme mode). Entering the programme mode during communication will
abort the communication.
Note: Pressing the Ö and # keys together within five seconds of power up defaults
the master code and the engineer code to factory settings.
Pressing the Ö and # keys together within five seconds of leaving the engineer
mode also defaults the master and engineer codes to factory settings. Pressing
any key within the five second period extend it for a further five seconds.
If Group 5 - Option 4 (Hotkey Enable) is enabled, pressing Ö and # activates
the keypad panic facility . The keypad panic facility will not operate within
five seconds of leaving engineer mode or powering up the system.
Defaulting Codes
To default the Master User Code and the Engineer Code press the Ö and # keys
together within five seconds of power up. Hold both keys down for approximately two
seconds until two beeps are emitted. The Engineer Code defaults to 9090 and the
Master Code to 1234.
Note: For important information on Ö and # key operation see the note above.