Group 7 — Option 2 Dial Type
If this option is set to 0 the panel dials using Pulse dialling, also known as Rotary or
Loop Disconnect
If this option is set to 1 the panel dials using DTMF Dial, also known as Tone.
Note: Although this equipment can use either Pulse or DTMF dialling, only the
performance of the DTMF signalling is subject to regulatory requirements for
correct operation. It is therefore recommended that the equipment is set to use
DTMF dialling.
This option defaults to 1 (DTMF).
Group 7 — Option 3 Prevent Full Set if Line Fail
If disabled (0) the panel can be full set if a Line Fail has been detected.
If enabled (1) the panel can not be full set if a Line Fail has been detected.
This option defaults to 0 (disabled).
Group 7 — Option 4 Bell Delay
If this option is disabled (set to 0) there is no Bell Delay.
If this option is enabled (set to 1) there is a 10 minute delay between an alarm and the
activation of internal and external sounders. During this time the entry beeps sound if
the unsetting procedure is initiated and the Bell Delay is overridden if a Line Fail or
Comms Fail condition occurs.
This option defaults to 0 (no Bell Delay).
Note: Bell Delay is over-ridden in set states that are not programmed to
communicate (Group 7 - Option 6).
Group 7 — Option 5 Exit Terminate
If Push-to-Set is enabled (options 1 – 4), Full, Part or Night set exit times for the
selected will be set to infinity. For Full Set this overrides the value programmed in the
Exit Time option (Group 4 System Options — Option 1 Exit Time).
Setting of the system is terminated when a Push-to-Set zone is opened during the exit
time. There is a five second delay between the closing of the Exit Terminate zone and
the setting of the system.
Note: The operation (opening and closing) of Exit Terminate zones has no effect on
the system except during the setting procedure.
The options for Push-to-Set are:
0. Push-to-Set not used.
1. Push-to-Set on Full Set only.