Section 2: Installing the Accord XPC
Ancillaries Pack
The Accord xpC control panel comes with an ancillaries pack. It contains ten zone
links, a cable clamp (with two self tapping screws), two M4×20 mm lid screws,
battery connector leads and 16, 1K resistors.
Initial Mounting
Use the keyhole slot in the enclosure base to position the control panel enclosure.
Three mounting screws (not provided) are required to mount the enclosure base. Fix
one of the screws into the mounting surface, this will be used for the top, keyhole
mounting hole. Hang the enclosure base onto the mounting screw ensuring that the
screw sits in the narrow portion of the keyhole.
All cables should be brought into the enclosure base via the cable entry points shown
in figure 2.1. There are six cable entry holes for the entry of alarm cables. There is
one a.c. mains cable entry point located below the mains terminal block.
Figure 2.1 Accord XPC Enclosure Layout
Note: Leave about 60 mm above the control panel enclosure to enable the enclosure
lid to move on its hinges for removal and replacement.