42
0. No Zone.
1-8. Number of zone for double knock.
This option defaults to 0 (No Zone).
Group 9 — Option 4 User Omit Zone
This option has two settings:
0. Zone omit disabled, zones cannot be omitted by the user.
1. Zone isolation enabled, zones can be omitted by the user.
This option defaults to 1 (enabled).
When this option is disabled, three error beeps are heard after a user code is entered
and 6 (Omit) is selected.
Note: This option only affects users. The engineer code can omit zones regardless of
this option setting.
Group 9 — Option 5 Restore Signals on Unset or Reset
This option has two settings:
0. Restore on Unset.
1. Restore on Reset.
If set to 0 (Restore on Unset) the restore signal is sent, after an alarm condition during
a set state, when a user code is entered to unset the system, or at the end of the confirm
time window if an unconfirmed alarm has occurred.
If set to 1 (Restore on Reset) the restore signal is sent after an alarm condition during a
set state, when the system is Reset.
This option affects High Speed format only.
This option defaults to 0 ((Restore on Unset) - required by DD243).
Group 9 — Option 6 Entry Deviation Permitted
This option has two settings:
0. Entry deviation not permitted.
1. Entry deviation permitted.
If set to 0 (Entry Deviation not permitted), deviation from an entry route during entry
or supplementary entry periods will result in a Full Alarm Condition.
Entry Deviation permitted (1), starts a 30 second time window when deviation occurs.
During the 30 seconds an internal alarm warning should sound. External bells/
communications/triggers, will be withheld until 30 seconds has passed or the entry
period ends. Entering a valid code before a full alarm condition, prevents communica-
tion of triggers.
This option defaults to 1 (Entry Deviation permitted) - required by DD243.