ADEMCO Accord Installationshandbuch Seite 35

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 78
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 34
27
Assistance: Press 4+6 together. Keypad displays scrolling LEDs ( ) with fast pulse
tone.
Fire: Press 7+9 together. Keypad displays scrolling LEDs ( ) with slow pulse tone .
Panic: Press Ö and # together. All LEDs (PA) illuminate and a constant tone emits.
Buttons must be held down for two seconds for Hotkey Operation.
This option defaults to 0 (disabled).
Note: For important information on Ö and # key operation see the note in “An
Introduction to Programming the Accord xpC”.
Group 5 — Option 5 Auto Omit Keypad
When enabled (set to 1) the keypad is omitted if 20 keys are pressed without a valid
code being entered, this does not include the # key. The keypad is omitted from the
system for 10 minutes and affects all keypads on the system. Keypad auto omit is
indicated by flashing zone LEDs (– –) on the keypad.
A keypad auto omit may be cancelled by operating a zone programmed as Keyswitch.
This option defaults to 0 (disabled).
Group 5 — Option 6 Bell Output
When set to 0 the Bell output is negative applied (positive removed).
When set to 1 the Bell output is negative removed (positive applied).
This option defaults to 0 (negative applied).
Group 5 — Option 7 Alarm Trigger Output
When set to 0 the Alarm Trigger output is negative applied (positive removed).
When set to 1 the Alarm Trigger is negative removed (positive applied).
This option defaults to 0 (negative applied).
Note: Only valid when Alarm trigger Output (Group 4 - Option 7) is set to 3.
Group 5 — Option 8 System Reset for Day Tampers
This option determines how the system may be reset after a tamper condition that
occurs when the panel is unset and has four modes:
0. Customer.
1. Engineer.
2. Technistore.
3. Engineer or Technistore.
Set to 0 (Customer): User code resets the system after day tamper activations.
Set to 1 (Engineer): User code can cancel a day tamper activation but the engineer
code is required to reset the system.
Seitenansicht 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 77 78

Kommentare zu diesen Handbüchern

Keine Kommentare