Section 7: Handing the System Over to
the User
Fill In the User Instructions!
User Instructions come with every Accord xpC panel. It explains end-user functions in
an easy to understand format.
To minimise false alarms and unnecessary call outs it is important that the user is
familiar with the operation of the system. It is strongly recommended that the engineer
explains fully the operation of the system to the user.
Appendix A: Specifications
Panel Specification
Physical Width: 195 mm
Height: 285 mm
Depth: 90 mm
Electrical Mains Input: 230 V a.c. (±10%) 50 Hz
Back-up Battery: Up to 7.2 Ahr 12 V Sealed Lead-Acid
Current Drain (control only): 30 mA (normal use)
External Sounder Output: 12 V – 1 A max Switched –ve
Strobe output: 12 V – 500 mA max Switched –ve
Aux Power Output: 12 V – 500 mA max
Trigger Output: 12 V – 5 mA max (Normally 0 V)
Fuses Mains: 200 mA – 20 mm Anti-surge (IEC 127)
Battery: 1 A – 20 mm Anti-surge (F1)
Speaker/Strobe: 500 mA – 20 mm Anti-surge (F2)
Keypad/Aux Power: 500 mA – 20 mm Anti-surge (F3)
Note: Due to continued product development and improvements these specifications
may change without notice.