Programming Fields
To programme a parameter select the programming group. Enter the second digit to
choose the zone number, zone option or system option to be modified. Enter the third
digit to programme the zone type, zone option or system option.
yeKemaN
1snoitpoteSlluF
2snoitpOteStraP
3snoitpoteSthgiN
41snoitpOmetsyS
52snoitpOmetsyS
61snoitpOsmmoC
72snoitpOsmmoC
8sreggirTsmmoC
93snoitpOmetsyS
03snoitpOmetsyS
1#senoZFR
2#tseTkaoS
6#snoitpOmrifnoC
Note: If the keypad beeps twice the
information has been correctly
entered. If the control panel beeps
three times after making a
programme entry, either the entry
was invalid or too much time was
taken to enter the information.
Table 3.1 Programming Groups
Viewing Field Programming
To view the programme options in groups 1, 2, #2, 3, 4, 5, #6, 7, and 9; enter Engineer
mode and enter the group number then 00. The value for each option will display in
sequence.
To view the single option programming for groups #1, 6, 8 and 0, enter engineer mode
followed by the group number, then 0 followed by the option number.
Example: To View the Primary telephone number:
1. If not in Engineer Mode, enter the engineer code.
2. Enter the group number 6, press 0, then the option number 1.
3. The LEDs on the keypad, light to display the programmed telephone number, (Icon
keypad displays telephone number as a sequence of digits).
Changing Engineer Code
The engineer code is user 0 on the system.
The engineer code can be changed by entering 9090, then 8 (CODE), then 0 (LOG)
then a new four digit code; for example:
9090 8 0 5678
Engineer Code is now 5678
Two beeps confirm the code has been accepted.
The Programming Format
An easy to use Programming Format has been adopted, to make Accord xpC program-
ming as simple as possible. Each system parameter has been allocated to a Program-
ming group. To programme a parameter select the programming group, select the
parameter and enter the desired value.