Supervision
Selects if the device is to be monitored for presence. This should always be selected as
1 (ON) unless the zone is a portable panic button that may be taken out of range of the
receiver. In this case, program the supervision as 0 (OFF).
Loop Number
Selects which loop of the transmitter is being used for the selected zone. For most
transmitters this is 1 as there is only one detection loop (zone) in the transmitter.
However, devices such as the 5816H have 2 loops which can be assigned to two
separate zones on the panel. On the 5816H, the wiring terminals for an external
contact are loop one, and the built in reed switch is loop 2. Please see the installation
guide supplied with the transmitter for more information.
7 Digit Serial Number
is the unique number printed on the label attached to the wire free transmitter. When
entered, this number tells the panel to look at the appropriate loop on this transmitter
and no other, for this particular zone.
For example, to tell the panel that zone 3 is to be a supervised RF zone using loop 1 on
a detector with serial number 0236187, the following sequence should be entered:
#1 3 1 1 0236187.
When a zone is successfully programmed as an RF zone, the hardwire terminals for
that zone will be ignored.
Clearing RF Zone Programming
To remove RF programming from a zone, program the RF parameters for that zone
with the supervision and loop parameters as 0. For example, to clear the RF program-
ming for zone above, and return it to a hardwire zone, the following sequence should
be entered:
#1 3 0 0.
Zone Programming - Group #2 Soak Test
This programming group enables the 14 day soak test function for each individual
zone on the system.
In programming mode:
The first two digits entered are #2 for Soak Test
The third digit entered is the zone number 1 - 8
The fourth digit entered is 0 or 1 to select soak test on that zone.
Selecting 0 for this option switches off the soak test function for that zone and the
zone will behave normally.
Selecting 1 for this option switches on the 14 day soak test function for that zone. The
zone will then behave as follows: