ADEMCO 4140XMPT2 Bedienungsanleitung Seite 96

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 132
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 95
96
Bypass commands
NOTE: Activation times 1 (Begin), 2 (End), 3 (During) are the only valid
choices for these commands. Note the following if 3-During activation time is
selected: Auto bypass will bypass the zone(s) at the beginning of the window
and unbypass the zone(s) at the end of the window. Auto unbypass will
remove the bypass of the zone(s) at the beginning of the window and will
restore the bypass of the zone(s) at the end of the window.
Action Code Action Specifier
30 Auto bypass - Zone list Zone list #
31 Auto unbypass - Zone list Zone list #
Open/close / Access
NOTE: Activation time 3 (During) is the only valid choice for these commands.
Action Code Action Specifier
40 Enable Opening Window by partition Partition(s)
41 Enable Closing Window by partition Partition(s)
42 Enable Access Window for Access group(s) Group(s)
3 ) Enter the desired Activation time, which refers to when the action is to
take place relative to the time window. Select from:
Activation
Time Description
1 Beginning of time window
2 End of time window
3 During time window active period only (On at beginning of
window, off at end).This can be used in conjunction with the
arm, disarm or bypass commands to control a part of the system
during the window. For example, if bypass is selected to
activate during the window, the zones in the zone list will be
bypassed at the beginning of the window and unbypassed at
the end of the window.
4 Beginning and end of time window (ex. -Coffee break buzzer).
In this example, if relay pulse was selected, the relay would
pulse for 2 seconds at the beginning of the window, signaling
the beginning of the coffee break. At the end of the window it
would pulse again, signaling the end of coffee break.
Time Driven Events Worksheet
Sched. Time Day(s) Action Action Activation
Num. Window M T W T F S S H Desired Specifier Time
1
2
3
.
.
20
Seitenansicht 95
1 2 ... 91 92 93 94 95 96 97 98 99 100 101 ... 131 132