ADEMCO 4140XMPT2 Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 132
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
– 20 –
The following table highlights the features of each receiver.
FEATURE 4280 series 4281 series 5881 series
Wiring Connects to polling
loop
Connects to
console lines
Connects to
console lines
House ID set via DIP switches programmed via #93
Menu Mode.
programmed via #93
Menu Mode.
Receiver Address Set by cutting blue
jumper in 2nd
receiver. Enabled
via fields 1*26 &
1*27.
Set via DIP
switches. Enabled
via #93 Device
Programming.
Set via DIP
switches. Enabled
via #93 Device
Programming.
Cover Removal Causes alarm or
trouble depending
on response type
assigned.
Does not cause
alarm or trouble.
Does not cause
alarm or trouble.
Go/No Go Mode Requires cover
removal.
Automatic upon
entering test mode.
Automatic upon
entering test mode.
Spatial Diversity No. Requires 2
receivers for
redundancy or to
expand area of
coverage.
Yes. Eliminates
nulls and voids. 2nd
receiver expands
coverage area or
provides additional
redundancy.
Yes. Eliminates
nulls and voids. 2nd
receiver expands
coverage area or
provides additional
redundancy.
Transmitter ID Set via DIP
switches.
Set via DIP
switches.
Serial numbers are
"learned" by the
system.
4280 Series Receiver
4280 is not recommended
for new installation; receiver
is scheduled to be
discontinued.
Important: Note that if using two RF Receivers, one of them must be
powered from auxiliary power, so as not to exceed the 64mA polling loop
current rating.
Set field 1*32 to 0.
For more information regarding the 4280 installation, refer to the installation
instructions provided with the 4280.
If using a 4280-8, only up to 8 zones can be enabled as RF zones. If more than
8 zones are enabled, the message "SET-UP ERROR" (or E8 on non-alpha
consoles) will be displayed.
Refer to the maximum polling loop wire runs described in the POLLING LOOP
section when connecting 4280s to the polling loop.
IMPORTANT: The maximum combined polling loop run is 4000'. If using
shielded wire, the maximum is 2000'.
4281 Series Receiver Set field 1*32 to 1.
Using #93 Menu mode–Device Programming, select as RF device type.
Set house ID via #93 Menu Mode.
Set receiver's device address using its DIP switches. Lower numbered
address is primary receiver (supervisory fault ID 90, 91). Higher numbered
address is secondary receiver (receiver fault ID 88, 89).
Important: 4281 microprocessor must have part number N5334Vx, where x is
any number. The microprocessor is located just above the DIP switch on the
PC board.
5881 Series Receiver Set field 1*32 to 2.
Using #93 Menu mode–Device Programming, select as RF device type.
Set house ID via #93 Menu Mode (needed for 5827 keypad only).
Set receiver's device address using its DIP switches. Lower numbered
address is primary receiver (supervisory fault ID 90, 91). Higher numbered
address is secondary receiver (receiver fault ID 88, 89).