Remote Keyswitch If the keyswitch option is selected (field *15), the alarm trigger outputs are
disabled.
An optional Remote Keyswitch can be used for remote arming and disarming of
the system. Note that keyswitch arming may only be used in one
partition.
If used, program field *15 must be set to the desired partition to enable the
keyswitch option, and the 4146 keyswitch's normally open momentary switch and
LEDs must be connected to Zone 7 and to the J7 connector trigger outputs
respectively. A 2k EOL resistor must be connected across the switch regardless
of whether or not zones 2-8 are selected to use EOL resistors. See diagram
below.
Note that the system automatically assigns zone type 10 to zone 7 if keyswitch is
used.
A momentary short across this zone will arm the system in the "AWAY" mode. If
the short is held for more than 3 seconds, the system will arm in the "STAY"
mode. (i.e. all zones designated as zone types 4 or 10 will be automatically
bypassed). After the system has been armed, the next time zone 7 is shorted,
the system will disarm.
An optional closed-circuit tamper switch (model 112) can be wired in series with
zone 7, so that, if the switchplate is removed from the wall, the tamper will open,
disabling keyswitch operation until the system is next disarmed from the console.
Note: Only one keyswitch with LEDs can be supported by the system's
power supply.
Note: Open/close reporting for keyswitch is enabled in field *40, and the
keyswitch reports as user 0.
LED indications are defined as follows:
Green Red Meaning
Off Off Disarmed & Not Ready
On Off Disarmed & Ready
Off On Steady Armed Away
Off Slow Flash Armed Stay
Off Rapid Flash Alarm Memory
1 2 3 4 5 6 7 8 9
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
GROUND
OUT 1
GROUND
OUT 2
GROUND
OUT 3
GROUND
OUT 4
J7 CONNECTOR
(ARMED) (READY)
RED GREEN
820 820
TAMPER
SWITCH (N.C.)
LOCK
SWITCH (N.O.)
2000
OHMS
EOLR
TO TERM 20
TO TERM 19
TO ZONE 7
{
4146 KEYSWITCH
(NOT UL LISTED)
IF KEYSWITCH IS USED.
1. OUT 1 CAN STILL BE USED TO PROVIDE
GROUND START, OPEN/CLOSE
(SEE FIELD 1*46).
2. OUT 2, 3, 4 NO LONGER PROVIDE ALARM
STATUS INDICATIONS. OUT 2 & 4 OPERATE
KEYSWITCH LEDs. OUT 3 IS NOT USED.
ONLY 1 KEYSWITCH CAN BE USED.
3. ZONE 7 IS NO LONGER USABLE AS A PRO-
TECTIVE ZONE.
BROKEN LINES REPRESENT
INSTALLER WIRING CONNECTIONS
N/U
4142TR CABLE
TO AUX POWER
TERMINAL 6