– 30 –
START STOP
ACTION DESIRED A E V Z L Z T P Z L Z T P
=You must define a Start zone list (zl) for these
applications to work properly.
*Can be used to turn on lights in a specific room or area.
For example you can automatically turn on the basement
light on entry.
CHIME
Close relay for 2 seconds during chime. (Chime mode
must be turned on at control)
10038X000X
Chime on Specific zones:
Zones in zone list (x) close relay for 2 seconds on faults* 1 2 X 00 X 0 00 X
*Will activate relay for any zone type plus panics on 5801
whether control is armed or disarmed. (Console panics will
not activate a relay with the configurations above.)
Zones in zone list (x) close relay for 2 seconds on alarms 1 1 X 00 X 0 00 X
Zones in zone list (x) close relay for 2 seconds on troubles 1 3 X 00 X 0 00 X
BELL OUTPUT
Zones in zone list (x) close relay on alarms and reset at bell
timeout or when disarmed by any either partition.
2 1 X 00 X 0 36 X
Zones in zone list (x) pulse relay on alarms and reset at
bell timeout or when disarmed by any partition.
31X00X036X
Close relay after any burglary alarm and reset when
disarmed by any partition.
2 0 0 33 X 0 22 X
Close relay after any burglary alarm and reset at bell
timeout or when disarmed by any partition.
20033X036X
*Response types 06,08, and 09 will not activate relay. If
PULSE relay is desired, enter a 3 in A(action).
STROBE LIGHT
Zones in zone list (x) close relay after alarms and reset
when disarmed by either partition. (Latching relay for
strobes)*
2 1 X 00 X 0 22 X
Zones in zone list (x) pulse a relay after alarms and reset
when disarmed by either partition.*
31X00X022X
*Relay will activate for burglary, fire, and panic alarms if
programmed into zone list.
Zones in zone list (x) close relay on alarms and reset with
key entry of security code + # + 7 + 1
2 1 X 00 X 0 34 X
SYSTEM STATUS INDICATORS
Close relay when ARMED-AWAY, reset when
DISARMED. (Any partition)*
20021X022X
Close relay when ARMED-STAY, reset when DISARMED.
(Any partition)*
20020X022X
*If PULSED relay is desired, enter a 3 in A(action).
Bypassing a zone causes relay to close and will reset with
a disarm sequence (code + off.)
20040X022X
CONFIRMATION OF ARMING DING
Close relay for 2 seconds at end of exit delay time after
system is armed
10031X000X