– 124 –
Section 6. SPECIFICATIONS
4140XMPT2 CONTROL
Physical: 12-1/2"W X 14-1/2"H X 3"D (318mm x 368mm x 76mm)
Electrical:
VOLTAGE INPUT: From Ademco No. 1361 Plug-In Transformer (use 1361CN in Canada) or 4300 transformer (for
X-10 installations) rated 16.5VAC, 40 VA.
ALARM SOUNDER OUTPUT: 10VDC-13.8VDC, 2.8 amps max. (UL1023, UL609 installations), 750mA less aux. current
drain (UL985 installations).
AUXILIARY POWER OUTPUT: 9.6VDC-13.8VDC, 750mA max.
BACK-UP BATTERY: 12VDC, 4AH or 7AH gel cell. 467 (12V, 4AH) or 712BNP(12V, 7AH) recommended.
STANDBY: 4 hours min. with 750 mA aux. load using 7 AH battery.
CIRCUIT PROTECTORS: thermal circuit breakers are used on battery input to protect against reverse battery
connections and on alarm sounder output to protect against wiring faults (Shorts).
A solid state circuit breaker is used on auxiliary power output to protect against wiring faults
(shorts).
DIGITAL COMMUNICATOR
FORMATS SUPPORTED:
ADEMCO HIGH SPEED
ADEMCO 4+2 EXPRESS
ADEMCO LOW SPEED
ADEMCO CONTACT ID
SESCOA
RADIONICS LOW SPEED
LINE SEIZE: Double Pole
RINGER EQUIVALENCE: 0.7B
FCC REGISTRATION NO.: AC398U-68192-AL-E
DOC LOAD NO.: 5
6128 REMOTE CONSOLES
Physical:
Width: 5.75 inches (146mm)
Height: 4.75 inches (121mm)
Depth: 1 inches (26mm)
Electrical: Voltage Input: 12VDC
Current Drain: 25 mA
Interface Wiring:
RED (R): 12VDC input (+) auxiliary power
GREEN (G): Data to control panel
YELLOW (Y): Data from control panel
BLACK (B): Ground (-)
6139 Remote Console
Physical:
Width: 6.25 inches (159mm)
Height: 4.75 inches (121mm)
Depth: 1.25 inches (32mm)
Electrical: Voltage Input: 12VDC
Current Drain: 100 mA
Interface Wiring:
RED: 12VDC input (+) auxiliary power
BLUE: Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from supplemental power supply.