6127 REMOTE CONSOLE
Physical:
5.75” W
x 4.75”H X 1D
(146mm x 121mm x 26mm)
Electrical:
Vottage Input 12VDC
Current Drain: 20 mA
Interface Wiring:
RED:
12VDC input (+) auxiliary
power
BLUE: (If present) Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK Ground and (-) connection from supplemental
power supply.
6137 REMOTE CONSOLE
Physical:
6.25” W X 4.75H
X 1 D
(159mm x 121mm x 26mm)
Electrical:
Voltage Input: 12VDC
Current Drain: 85 mA
Interface Wiring:
RED: 12VDC input (+) auxiliary power
BLUE:
(If present) Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from supplemental
power supply.
6139 REMOTE CONSOLE
Physical:
6.25”
W X 4.75”H X 1.25” D
(159mm x 121mm x 32mm)
Electrical:
Voltage Input: 12VDC
Current Drain: 100 mA
Interface Wiring:
RED:
12VDC input (+) auxiliary power
BLUE: (If present) Not Used
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection”from supplemental
power supply.