Enter 1 to enable Rotary back-up if communicator is not successful on dialing
W/Rotary Backup
using TouchTone DTMF on first attempt. Enter O if this option is not be to be
(Q=no/l=yes)
used.
1.34 communication
Enter O, 1, or 2, in accordance with the following:
Split Report
O= split reporting disabled; 1 = alarm, alarm restore& cancel reports sent to
Selection
primaty Telco number, all others to secondary Telco number 2 = operdclose &
(Q/1/2)
test reports sent to secondary Telco number and all other reports to primary. See
*51 for spliffdual reporting comments.
135.1 .39 Not Used
14O Armed Stay Dialer The dialer can be made to send a report
when the system is armed in the STAY
Report (First Digit)
mode,as follows:
If any Low Speed reporl is beong used, the report codes are assigned in this 2-
digit field (and field 1*41 below), which is similar to programming a
CLOSE report
in fields 81 and 82.
If Ademco High Speed format is being used, a normal closing report will be sent.
If Ademco Contact ID is used, a new code, R441, will be sent. Note
that 685
receivers that do not have software revision 4.5 or higher will print an error
message in place of the English text.
141 Armed Stsy Dialer
See
Field 140,
Report (Second
Digit)
1,42.1 43 Not Used
1*44 RF Keypad Tamper
Enter 1 to enable tamper detection on wireless keypad. Enter O if tamper
Detect
detection is not desired. If this feature is enabled, any attempt to tamper by
(Q=no/l=yes)
means of many trial entries at a wireless keypad will be blocked by the control
panel. If more than 40 key depressions are received without a valid sequence
(arm, disarm, etc.), the Control panel will disable the wireless keypad. The inhibit
is removed once a valid key sequence is received from a wired keypad.
1.45 Console
Enter 1 if beeps from the consoles during exit delay is desired. Enter Ofor no
Annununciation
console sound during exit delay.
During Exit Delay
(Q=no/1=yes)
1*46
Auxiliary Output
Enter Oif ground start output is required; enter 1 if the TERMINAL 9 output will be
Enable
used to produce an operdclose trigger, 3 if zone 1 is to use EOLR supervision.
(ollf~
“2” is unused.
NOTE: Onlv one of the above oDtions can be active within a svstem.
1*47 Chime
Enter 1 for chime annunciation using the external alarm sounder (if not desired,
Annununciation On
enter O).
External Sounder
(Q=no/l=yes)
1*48 Wireless Keypad
Enter 1 if wireless keypad is not to be used (disable keypad). Enter Oif wireless
Disable
keypad is used.
(Q=no/1=yes)
1s49 DisabIe Trouble
Enter 1 to disable trouble sounding for transmitter check-in failure; enter O if
Sounder For
RF
audible trouble sounding is desired. Must be “O”for UL.
Supervision
(O=no/l=yes)
1*5O Babysitter Code Enter 1 if it is desired that User 22 cannot disarm the system unless the system
(Q=no/1=yes)
was armed by User 22.