1●33 Touchstone
Enter 1 to enable Rotary back-up if communicator is not successful on dialing
W/Rotary Backup
using TouchTone DTMF on first attempt. Enter O if this option is not be to be
(Q=no/l=yes)
used.
1.34 communication
Enter O, 1, or 2, in accordance with the following:
Split Report
O= split reporting disabled; 1 = alarm, alarm restore& cancel reports sent to
Selection
primaty Telco number, all others to secondary Telco number 2 = operdclose &
(Q/1/2)
test reports sent to secondary Telco number and all other reports to primary. See
*51 for spliffdual reporting comments.
1●35.1 .39 Not Used
1●4O Armed Stay Dialer The dialer can be made to send a report
when the system is armed in the STAY
Report (First Digit)
mode,as follows:
If any Low Speed reporl is beong used, the report codes are assigned in this 2-
digit field (and field 1*41 below), which is similar to programming a
CLOSE report
in fields ●81 and ●82.
If Ademco High Speed format is being used, a normal closing report will be sent.
If Ademco Contact ID is used, a new code, R441, will be sent. Note
that 685
receivers that do not have software revision 4.5 or higher will print an error
message in place of the English text.
1●41 Armed Stsy Dialer
See
Field 1●40,
Report (Second
Digit)
1,42.1 ●43 Not Used
1*44 RF Keypad Tamper
Enter 1 to enable tamper detection on wireless keypad. Enter O if tamper
Detect
detection is not desired. If this feature is enabled, any attempt to tamper by
(Q=no/l=yes)
means of many trial entries at a wireless keypad will be blocked by the control
panel. If more than 40 key depressions are received without a valid sequence
(arm, disarm, etc.), the Control panel will disable the wireless keypad. The inhibit
is removed once a valid key sequence is received from a wired keypad.
1.45 Console
Enter 1 if beeps from the consoles during exit delay is desired. Enter Ofor no
Annununciation
console sound during exit delay.
During Exit Delay
(Q=no/1=yes)
1*46
Auxiliary Output
Enter Oif ground start output is required; enter 1 if the TERMINAL 9 output will be
Enable
used to produce an operdclose trigger, 3 if zone 1 is to use EOLR supervision.
(ollf~
“2” is unused.
NOTE: Onlv one of the above oDtions can be active within a svstem.
1*47 Chime
Enter 1 for chime annunciation using the external alarm sounder (if not desired,
Annununciation On
enter O).
External Sounder
(Q=no/l=yes)
1*48 Wireless Keypad
Enter 1 if wireless keypad is not to be used (disable keypad). Enter Oif wireless
Disable
keypad is used.
(Q=no/1=yes)
1s49 DisabIe Trouble
Enter 1 to disable trouble sounding for transmitter check-in failure; enter O if
Sounder For
RF
audible trouble sounding is desired. Must be “O”for UL.
Supervision
(O=no/l=yes)
1*5O Babysitter Code Enter 1 if it is desired that User 22 cannot disarm the system unless the system
(Q=no/1=yes)
was armed by User 22.
-55-