Ground Start Module
Not intended for use in UL Listed applications.
An optional 675 Ground Start module
can be used for installations having
telephone lines which require ground start instead
of loop start operation to
obtain dial tone from the telco central office. If used, program field 1
46 must be
set to “O” and the 675 Ground Starl Module must be connected to the control’s
terminal 9 (zone 1 high side)*, to auxiliary power, and to the “RINGmside of the
telephone line as shown in Figure 5.
Wired Zone 1 cannot then be used as a protection zone.
Use the following procedure to determine which side of the telephone line is the
“RING” side:
a) Connect the “+” lead of a DC voltmeter to earth ground, and the “-” lead to one
side of the telephone line.
b) The wire which reads +50VDC is the “RING” side.
When the control has a message to transmit to the central station, it will seize the
line, go off hook, and then trigger the 675 module to connect the “RING” side of
the telephone line to earth ground. The control will cause the module to break the
connection between “RING” and earth ground when a dial tone is obtained.
INCOMING TELCO LINES
/
n
/
/ /
/1
/’
‘RJ31x
JACK
USE RJ31X
CORD NO.
MO-366.
LOCALPHONES
Figure 4. PHONE LINE CONNECTIONS
TO TERM 25
BROWN
t
Figure 5. GROUND START CONNECTIONS
-25-