1*O9 Response Type For Three 2-digit field entfies:89 (2nd Receiver),90 (lst Receiver),9l (lst Receiver).
Zones 89-91
For UL applications, use of 1 or 2 RF RCVRS requires enabling their respective
(See Field *O5 for
faults (88-91 ) as applicable (type 5).
response types)
88&90=
RCVR not receiving transmitter signals. 89 & 91 = RCVR not
responding, bad connection to panel.
1*1o.1*17 Not Used
1*18 Select Wireless For
Enter 1 to enable a zone as wireless, otherwise enter O for hard-wire zones. If
Zones 1-8
zones 1-8 are to be used as wired zones, be careful not to select those zones for
(See field 1
●25)
RF because they will then be ignored,
since the wireless option
takes
precedence over hard-wire zones.
NOTE: Only up to 8 wireless zones (4281M or H) or up to 4 wireless zones
(4281 L) maybe selected within the range of 1-83.
1*19 Select Wireless For
(See field 1*18)
Zones 9-16
1*2O Select Wireless For (See field1*18)
Zones 17-24
1●21 Select Wireless For (See field 1*18)
Zones 25-32
1●22 Select Wireless For
(See field 1*18)
Zones 33-40
1*23 Select Wireless For (See field 1*18)
Zones 41-48
1*24 Select Wireless For (See field 1•18)
Zones 49-56
1*25 Select Wireless For (See field 1
●18)
Zones 57-63
1●26 First RF Receiver
Enter 1 if first Receiver is installed. Enter O if no Receiver is installed.
Select (Q=no/1=yes)
1●27 Second RF Receiver
Enter 1 if 2nd 4281 Receiver is installed. Enter O if only
one or no Receiver is
Select (Q=no/1=yes)
installed, If
second Receiver is installed, set DIP switch on 4281 (see Fig. 2).
1●28 RF Transmitter Low
Enter O if audible beep and display annunciation upon RF transmitter low battery
Battery
condition is desired only in disarmed state. Enter 1 if audible beep and display is
Annunciation
desired in both armed and disarmed states. Must be 1 for UL.
(Qfl)
1,29 Transmitter LOW
Enter 1 if a trouble message for RF transmitter low battery conditions is to be
Battery Report
sent to the central station. Enter O if no report for transmitter low battery is
Enable
desired.
Note that a trouble message will be sent for a transmitter supervision
(Q=no/1 =yes)
failure independent of this selection. Must be”1” for UL.
1.30 RF Receiver
Enter the check-in monitoring interval in 2-hour increments; enter 02-15 (entry
Supervision Check-
times 2=4-30 hours). Failure of a receiver to receive any RF signal within the time
In Interval
entered will result in activation of the response type programmed for zone 90 for
(00; 02-1 5)
the first Receiver and zone 88 for the second
Receiver and their related
communication reports. Enter 00 to disable supervision. NOTES:
If a zero is
programmed, supervision of the RF receiver will be disabled (response types for
zones 88 and 90 are disabled). Default=6. Max. “6” (12 hr) for UL.
1●31 RF Transmitter Enter the check-in monitoring intetval in 2-hour increments; enter 02-15 (4-30
Check-In Interval
hours). Failure of an individual transmitter to send a supervision signal within the
(00; 02-15)
time entered will result in a trouble response and related communication repoti.
Entry 00 disables transmitter supervision. Max. “6” (12 hr) for UL. DefauIt=12.