37 Download Command Eight single-digit field entries:
Enables
Dialer Shutdown, System Shutdown, Not Used (0), Remote Bypass, Remote
@=yes/ O=no)
Disarm, Remote Arm, Upload Program, Download Program.
See field 153 for Callback disable option. For UL installations, Upload &
Download must be enabled; all others must be disabled.
Each of the various remote (from the central station) functions can either be
enabled or disabled. Disabling a function means that the central station will not
be able to perform that function with respect to this system. Enter 1 to enable a
function, and O to disable a function.
For UL installations, all entries must be O.
38 Inhibit Bypass Of A Entering a zone number (01-31 only) prevents that zone from being bypassed by
Zone
the user. Enter 00 if this feature is not desired (all zones can be bypassed). This
(m 01-31)
selection does not affect fire zones, which can never be bypassed.
39 Open/Close Reports
See field *4O
For Users 1-8
(l=yes/Q=no)
*4O
Open/Close Reports
Enter 1 for each
user which is to send open/close reports to the central station.
For Users 9-16
Note that user 7 must be enabled if either open/close reporting is desired for
(1=yes/ Q=no)
keyswitch arming, or if close reporting is desired for Quick Arm and Power
Up
arm, or if open/close reporting is desired for remote arm/disarm via downloading.
Note that users 16-70 are sent as user 15
for traditional communication formats.
To receive all user codes, Ademco Contact ID
reporting must be used.
*41 EOLR Disable
Enter O if end-of-line resistors are to be used. Enter 1 if end-of-line resistors are
(Zones 2-8)
not to be used (normally closed loops that detect only an open and do not require
(O=EOLR/1= no EOLR) end-of-line resistors). Must be “O”for UL.
Note: You must enter “O” (EOLR usage) in this field if a remote keyswitch is
being used (also see field
15).
42 Dial Tone Pause
Enter the desired wait time for dial tone detection as follows: Enter single digit, O
(Q/1/2)
= 5 seconds; 1 = 11 seconds; or 2 = 30 seconds. Must be Ofor
UL.
*43 Dial Tone Detect
Enter 1 if true dial tone detection is desired. Enter Oif only a delay before dialing
(I=true tone/O=pause)
(same as programmed in field *42) is desired. The
latter may be necessary in
high-noise environment Telco networks where
noise can be confused with dial
tone, resulting in premature dialing.
44 Ring Detection Count
Only applicable if central station initiated downloading will be used. Enter 00 to
(B O1-15)
disable ring detection. Enter 01-14 for ring counts of 1-14. Enter 15 to select
mode that gets around telephone answering machines connected to the same
phone line. In the latter mode, the system upon hearing one ring followed by
nothing, will not answer but will ready itself to pick up the next incoming call
received within the next 30 seconds on the first ring (the downloader calling
again).
*45
Primary Format
Enter the appropriate number for the primary format as follows: O=Low Speed;
(Qfl1213
1=Contact ID; 2=Ademco High Speed; 3=Ademco Express
46 Low Speed Format
Enter the appropriate value: O=Ademco Low Speed; 1=Sescoa/Radionics
(Primary) (Q/1)
47 Secondary Format
Enter the appropriate number for the secondary format: O=Low Speed; 1=Contact
(Q/1 /2f3)
ID; 2=Ademco High Speed; 3=Ademco Express
48 Low Speed Format
Enter the appropriate value: O=Ademco Low Speed; 1=Sescoa/Radionics
(Secondary) (Q/l )
49 Checksum Verification
Enter 1 to send a verification digit to validate the message at the receiver without
(Q= non = yes)
having to send two message rounds. NOTE: Selection applies to both primary
and secondary phone numbers, and is
valid for 3+1, 4+2, and Ademco High
Speed reports. Enter O if not desired.