ADEMCO VISTA-250FBP Einstellungsanleitung

Stöbern Sie online oder laden Sie Einstellungsanleitung nach Sicherheitszugriffskontrollsysteme ADEMCO VISTA-250FBP herunter. ADEMCO VISTA-250FBP Setup guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 72
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
V
VV
V
V
VV
V
I
II
I
I
II
I
S
SS
S
S
SS
S
T
TT
T
T
TT
T
A
AA
A
A
AA
A
-
--
-
-
--
-
1
11
1
1
11
1
2
22
2
2
22
2
8
88
8
8
88
8
F
FF
F
F
FF
F
B
BB
B
B
BB
B
P
PP
P
P
PP
P
V
VV
V
V
VV
V
I
II
I
I
II
I
S
SS
S
S
SS
S
T
TT
T
T
TT
T
A
AA
A
A
AA
A
-
--
-
-
--
-
2
22
2
2
22
2
5
55
5
5
55
5
0
00
0
0
00
0
F
FF
F
F
FF
F
B
BB
B
B
BB
B
P
PP
P
P
PP
P
Commercial Fire and Burglary
Commercial Fire and BurglaryCommercial Fire and Burglary
Commercial Fire and Burglary
Partitioned Security System with Scheduling
Partitioned Security System with SchedulingPartitioned Security System with Scheduling
Partitioned Security System with Scheduling
Programming Guide
K0376PRV2 7/09 Rev. B
Seitenansicht 0
1 2 3 4 5 6 ... 71 72

Inhaltsverzeichnis

Seite 1 - K0376PRV2 7/09 Rev. B

VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAAAAA--------111111112222222288888888FFFFFFFFBBBBBBBBPPPPPPPP VVVVVVVVIIIIIIIISSSSSSSSTTTTTTTTAAAAA

Seite 2

– 10 – *77 AUTO TROUBLE RESTORE [1] 0=disable, 1=enable *79 ZONE TYPE RESTORE ENABLES FOR ZONE TYPES 1-8 1 2 3 4 5 6 7 8

Seite 3

– 11 – 1*29 RF TX LOW BATTERY REPORTING [0] 1=enable; 0=disable Must be 1 for UL installations. 1*30 RF RCVR CHECK-IN INTERVAL [02]

Seite 4

– 12 – 1*76 CONTROL RELAY [00] | Relay will be pulsed for 2 seconds whenever code + [0] is pressed. Enter

Seite 5

– 13 – 3*13 FIRE SUPERVISORY RESPONSE TO OPEN/SHORT (Applies to Zone Type 18) [0] 0=Trouble on open/Supervisory on short 1=Supervisory on

Seite 6

– 14 – Partition-Specific Fields (Duplicate this page for each partition in the installation.) To program these fields, 1. Press *91 to select a pa

Seite 7 - Program Field Index

– 15 – 1*45 EXIT DELAY SOUNDING [1] 1=enable; 0=disable Produces quick beeping during exit delay if enabled. NOTES: Must be set to

Seite 8 - *04 ENABLE RANDOM TIMERS

– 16 – Programming With #93 Menu Mode NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers

Seite 9

– 17 – PROMPT EXPLANATION OUTPUT PGM? 1 = YES 0 = NO 0 For defining output relay functions. RLY VOICE DESCR? 1 = YES 0 = NO 0 Not U

Seite 10

– 18 – PROMPT EXPLANATION Each zone must be assigned a zone type, which defines the way in which the system responds to faults in that zone. Refer

Seite 11 - 1=enable; 0=disable

– 19 – PROMPT EXPLANATION 010 Silent ? 1 = YES 0 = NO 1 If you selected response type 1, 2, 3, 4, 5, or 10, this prompt will appear. Enter

Seite 12

–2– Table of Contents Programming Field Settings for UL864 Compliance 2 Recommended Programming Procedure... 6 Program Field Index ...

Seite 13

– 20 – PROMPT EXPLANATION 010 V-PLEX RELAY? 1 = YES 0 = NO If you selected input type 6, this prompt is displayed. Enter 1 if using a 4101SN Re

Seite 14

– 21 – 5800 Series Transmitters Loop Designations PROMPT EXPLANATION XMIT TO CONFIRM PRESS ✱TO SKIP Confirmation Option: This prompt only appears

Seite 15 - WINDOWS

– 22 – Expert Mode Zone Programming Expert mode allows you to program zones using the minimum number of screens and keystrokes. Expert Mode Zone Pr

Seite 16 - EXPLANATION

– 23 – PROMPT EXPLANATION ZN B M V A C E AD 010 2 1 1 0 1 1 01 Enter the remainder of the zone’s information, or press the [C]

Seite 17 - Zone Programming

– 24 – Report Code Programming All report codes are entered using #93 Menu Mode Programming, either through Report Code Programming, or through Zone

Seite 18 - Installation and

– 25 – Restore/Supervisory Codes PROMPT EXPLANATION RESTR, SUPV. CODE 1 = YES 0 = NO 0 Press [1] (Y) to enter Restore and Supervisory Codes

Seite 19 - Installation and Setup Guide

– 26 – PROMPT EXPLANATION Enter the rest of the codes in the same manner. Other report codes in System Group #1 are: • Opening (Disarm) Also, e

Seite 20

– 27 – PROMPT EXPLANATION Enter the rest of the codes in the same manner. Other codes in System Group #3 are: • Early Close • Late Open • Late C

Seite 21 - Programming Guide

– 28 – Alpha Descriptors Programming You can program a user-friendly English language description/location for all protection zones, relays, keypad p

Seite 22 - Expert Mode Zone Programming

– 29 – 4. Accept the word. To accept the word, press [6], which switches back to the alphabet list for the next word, or press [8] to store the com

Seite 23

–3– Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 ✱54 UNATTENDED MODE N 0 = disable 1 = enable

Seite 24 - Report Code Programming

– 30 – 3. Type the word using one of two methods as follows: a) Press [#], followed by the 2-digit entry for the first letter you would like to dis

Seite 25

– 31 – Alpha Descriptor Vocabulary (For entering alpha descriptors. To select a word, press [#] followed by the word's 3-digit number.) NOTE:

Seite 26

– 32 – Device Programming This menu is used to program keypads, receivers, and relay modules, etc. Device Address 00 is always set as an alpha keyp

Seite 27

– 33 – RF Expander PROMPT EXPLANATION 01 RF EXPANDER HOUSE ID 00 If you selected device type 03 (RF receiver), this prompt appears. Enter the 2-

Seite 28 - Alpha Programming

– 34 – The 6160/6160CR-2 Keypad displays the following prompts, which are sent by the Communicator to the control. NOTE: These prompts are for the 78

Seite 29 - READY TO ARM

– 35 – Output Programming The system supports up to 96 outputs. Outputs can be used to perform many different functions and actions. Each output m

Seite 30

– 36 – 2). ZONE TYPE/SYSTEM OPERATION (ZT). Instead of using a "RESTORE ZONE LIST," you can select a specific zone (response) type or syst

Seite 31 - Alpha Descriptor Vocabulary

– 37 – Choices for Start/Stop Zone Types and System Operations: 00 = No Response (Not Used) 22 = Disarming (Code + Off) 43 = Communication failure

Seite 32 - Device Programming

– 38 – PROMPT EXPLANATION 02 RELAY TYPE V-PLEX 0 Enter 0 for V-Plex (polling loop) devices. Enter 1 for (ECP) relay modules (4204/4204CF). Pre

Seite 33 - Figure 1

– 39 – Relay Voice Descriptors Each voice descriptor can consist of up to 3 words selected from the Relay Voice Descriptors and Custom Word Substitut

Seite 34

–4– Program feature or option Permitted in UL864? Y/N Possible settings Settings permitted in UL 864 2✱18 ENABLE GOTO FOR THIS PARTITION (partitio

Seite 35 - Output Programming

– 40 – Relay Voice Descriptors and Custom Word Substitutes Vocabulary Word Index Air ... 116 Alarm ...

Seite 36

– 41 – Scheduled Check-in The system can be programmed to call the downloader automatically, at a scheduled time. Once the connection is made, the do

Seite 37

– 42 – System Layout Worksheets Before programming any security system, you should first define the installation. To help you lay out a partitioned s

Seite 38

– 43 – PRINTER OPTIONS Parallel or Serial printer 12- or 24-hour Time format Printer On-Line (yes/no) 1200 or 300 baud Printer Baud Rate

Seite 39 - Relay Voice Descriptors

– 44 – ACCESS CODES and USER DEFINITIONS FOR PARTITIONS 3 and 4 Partition 3 Partition 4 4-digit Security Code Access Group 0; 1-8 3-Digit User # Aut

Seite 40

— 45 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 41 - Scheduled Check-in

— 46 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 42 - System Layout Worksheets

— 47 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 43

— 48 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 44

— 49 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 45

–5– NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the event log capacity, use the VISTA-

Seite 46

— 50 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 47

— 51 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 48

— 52 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 49

— 53 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 50

— 54 — Zone Information & Alpha Descriptor (3 words max.) Rpt. Code Bell/Relay Activation

Seite 51

— 55 — ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 995, 996, and 999 Enter yes/no for each partition-field *22 Zone No. Zone Type 1 2 3 4

Seite 52

— 56 — ZONE DEFINITIONS FOR RELAY SUPERVISORY ZONES 601-632 Zone No. Zone Type Report Code Zone Information and Alpha Descriptor (3 words max.) Zone

Seite 53

— 57 — ZONE DEFINITIONS FOR SUPERVISORY OF ECP DEVICE ZONES 800-830 Zone No. Zone Type Report Code Zone Information and Alpha Descriptor (3 words max

Seite 54

— 58 — Output Devices Worksheets Applicable only if relays (4204/4204CF) or V-Plex are used. Output Devices – Programmed in the #93 Menu Mode in th

Seite 55

— 59 — OUTPUT DEVICES WORKSHEET (cont’d) START STOP OUTPUT DEV # A EV/ZL Zone ZT / P ZL ZT / P Relay Group Restrict 0=V-Plex 1=4204/ 4204CF

Seite 56

–6– Recommended Programming Procedure The following is a step-by-step procedure recommended for programming your VISTA-128FBP/VISTA-250FBP system. 1.

Seite 57

— 60 — OUTPUT DEVICES WORKSHEET (cont’d) START STOP OUTPUT DEV # A EV/ZL Zone ZT / P ZL ZT / P Relay Group Restrict 0=V-Plex 1=4204/ 4204CF

Seite 58 - Output Devices Worksheets

— 61 — OUTPUT DEVICES WORKSHEET (cont’d) START STOP OUTPUT DEV # A EV/ZL Zone ZT / P ZL ZT / P Relay Group Restrict 0=V-Plex 1=4204/ 4204CF

Seite 59

— 62 — A = DEVICE ACTION 0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off; 4 = Toggle alternately between STAR

Seite 60

— 63 — Zone List 5: Started or stopped by zone numbers (enter 000 to end entries). Zone List 6

Seite 61

— 64 — Scheduling Menu Prompts To program schedules, enter Scheduling program mode by pressing [User Code] + # + 80 to display the first choice of th

Seite 62

— 65 — Scheduling Worksheets Time Windows Definitions Worksheet. The system provides 20 time windows that are defined with start and stop times. Th

Seite 63

— 66 — Holiday Schedule Worksheet: The system provides up to 16 holidays that can be assigned for the system. Each holiday can be assigned to any co

Seite 64 - Scheduling Menu Prompts

— 67 — Automatic Refresh: The system automatically updates the status of all Time-Driven Events upon any of the following occurrences: • Changing of

Seite 65 - Scheduling Worksheets

— 68 — Activation time: Refers to when the action is to take place relative to the time window. 1 = Beginning of time window 2 = End of time windo

Seite 66

— 69 — Partition/Windows Mon Tue Wed Thu Fri Sat Sun 3 Disarm Window Start Time HH:MM Stop Time HH:MM Arm Window

Seite 67

–7– Program Field Index On the following pages, the programming fields have been arranged in numerical order. Use this index to cross-reference the

Seite 68

— 70 — NOTES

Seite 69

— 71 — V250FBP-SOC-V5VISTA-128FBP / VISTA-250FBPSUMMARY OF CONNECTIONSTRANSFORMERW/ENCLOSUREADEMCO No.1451(supplied)INPUT: 120VAC, 60HZ,

Seite 70

ÊK0376PRV26ŠÊK0376PRV26ŠÊK0376PRV26ŠÊK0376PRV26Š K0376PRV2 7/09 Rev. B 2 Corporate Center Drive, Suite 100P.O. Box 9040, Melvi

Seite 71 - WARNING:

– 8 – VISTA-128FBP/VISTA-250FBP Programming Form Some fields are programmed for each partition (shown as shaded fields). If you are programming a mul

Seite 72 - ÊK0376PRV26ŠÊK0376PRV26Š

– 9 – *33 PRIMARY PHONE NUMBER Enter 0-9 fo

Kommentare zu diesen Handbüchern

Keine Kommentare