*13 Alarm Sounder Duration Enter the length of time an external sounder or the console’s sounder will sound
(01-1 5)
for all audible alarms (multiply entry 01-15 by 2 minutes for actual duration).
Minimum 4 minutes ror UL. Default= 04 (8 rein). See field 21
for Fire Timeout
option.
*14
Zone 8 Fast/Slow
Enter Ofor 350 msec response time or 1 for 10 msec response time. See WIRED
Response
ZONES in text.
(Q=slow/l=fast)
*15 Keyswitch Enable
Enter 1 in this field if using 4146 Keyswitch. Also, field *41 must be programmed
(Q=no/l=yes)
for EOLR supervision (0). Note that trigger operation is affected. See REMOTE
KEYSWITCH OPERATION in text. Also refer to Address 1*57.
*16 Confirmation Of
Enter 1 to enable 1/2 second external alarm sounding (“ding”) at the end of exit
Arming Ding
delay #1. Enter Oto disable the “ding”.
(Q=no/1 =yes)
*17 AC Power Loss Enter 1 if sounding at the console (rapid beeping) when AC power is lost is
Sounding
desired, Enter Oif no AC power loss sounding is desired.
(Q=no/l=yes)
*18 AC
Power Loss Alarm Enter 1 to have the external alarm sound after AC power has been out for 4 hours;
(Q=no/1=yes)
otherwise enter O(no alarm).
*19 AC Randomize
Enter 1 to randomize AC loss reporting between 10-40 min. after actual AC loss.
(Q=no/1=yes)
Enter Ofor normal AC loss reporting (about 2 minutes after actual AC loss).
*2O
Not Used
*21 Disable Fire Time-Out
Enter 1 to disable (no timeout) the alarm sounder duration (*13) for any zone
(Q=no/l=yes)
designated as a fire zone so that fire sounding continues until the system is reset.
Enter Oif normal alarm sounder duration should apply to fire alarms.
*22
Not Used
*23 Multiple Alarms
Enter 1 to enable the system to permit multiple audible alarms from a protection
(O=no/l=yes)
zone during one armed interval (as opposed to only one alarm). Enter Ofor only
one alarm. Note that multiple alarm soundings will not occur more frequently than
allowed by the alarm sounder duration, *13). This selection has no impact on the
number of communication messages transmitted.
*24
Not Used
*25 Burglary Trigger For When this field is disabled (0), Pin 6 (OUT 3) acts as a burglary trigger only.
Response Type 8
When enabled (1), pin 6 acts as a burglary trigger and also as a trigger for any
(1=enable/Q=disable)
zone assigned as type 8 (24-hour auxiliary) using non-burglary devices such as
water sensors, temperature sensors, and for personal errnergency.
*26
Intelligent Test Enter 1 if it is desired that no test report be sent if any other type of report was
Reporting
recently sent. Enter Oif test reports are to be sent at the set intervals, regardless
(Q=no/1=yes)
of other reports having been sent. Must be Ofor UL applications.
*27
Test Report Interval Enter interval in hours, 001–1 99; 000 = no report. This field selects the test
(w)
report transmission interval. For the test report desired, enter a test code in fields
*81 & *82, location 7. Enter 024 for UL.
Note: Automatic battery testing is
conducted every 24 hours, at which time AC power will be automatically removed
for 10 minutes and the battery will be tested under auxiliary current load.
*28
Power Up In Previous Enter 1 if, upon power-up, you want the system to assume the system status
State
prior to power
down. Enter O if you want the system to always power up in a
(O=no/l=yes)
disarmed state. When the system powers up armed, an alarm will occur
3
minutes after arming if a zone is faulted. When so armed, reports closing as User
#7 if open/close reporting for User #7 was enabled in field *39. Must be 1 for UL
applications. Note that if the previous state was armed AWAY or STAY, the
system may not respond to sensor changes for a small period of time (1-3 min.),
which allows time for sensors such as PIRs to stabilize.
-48-