ADEMCO Security System VISTA-15CN Einstellungsanleitung Seite 82

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 132
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 81
VISTA-15/VISTA-15CN Installation and Setup Guide
16–6
10 XMIT TO CONFIRM
PRESS
TO SKIP
The prompt to confirm appears.
This prompt appears only if you
asnswered “Yes” to the SET TO CONFIRM? prompt at the
bottom of page 16-4. To confirm, activate the loop input or button
that corresponds to this zone.
The system checks for a duplicate. If a duplicate exists, a long
error beep sounds.
Press [#] to back up and re-enter the serial and/or loop number.
If Serial or Loop
Numbers do not match
after activating the
transmitter
If the serial/loop number combination transmitted does not match
the serial and loop number entered, a display similar to the one
below appears. If the loop number does not match, it is also
displayed.
Keyd A022-4063
1
Rcvd A022-4064 1
If so, activate the transmitter’s loop input or button one or more
times.
If a match is still not obtained (i.e., summary display does not
appear), press the [#] key twice and enter the correct loop input
or, if correct, press [#] again and then enter the correct serial
number.
Zn ZT RC In:
L
11 00
10 RF:
-
Note that when editing, an “s”
next to the loop number indi-
cates that the transmitter’s
serial number has been
enrolled.
If the serial number transmitted matches the serial number
entered, the keypad beeps 3 times and advances to the Summary
display of the next zone to be programmed.
NOTE: Following the successful enrollment of each wireless device, remove ONE of the
serial number labels from the device and affix it in the appropriate column on the
ENROLLED TRANSMITTERS worksheet of the Programming Form; then enter the other
information (zone number, zone type, loop number, etc.) relevant to that device. This
information would be useful if any troubleshooting is needed later on. The installer may want
to consider leaving this worksheet at the site (in the panel cabinet).
To Remove a Zone
To either temporarily or permanently remove a zone from the system (5800 system):
1. Enter the programming mode:
Key Installer Code + 8 + 0 + 0 and press
56.
2. The following display appears:
SET TO CONFIRM?
0 = NO 1 = YES 0
Enter 0 for No; 1 for Yes.
3. The following display appears:
Enter Zn Num.
(00 = Quit) 10
Enter zone number to be removed. Example: 10.
Press [
] to continue.
Zn ZT RC In:
L
10 03
10 RF:
1s
This summary display appears.
Press [] to continue.
Seitenansicht 81