VISTA-15/VISTA-15CN Installation and Setup Guide
1–4
Chime/Chime by Zone
Chime, when on, normally sounds when any entry/exit or perimeter zone is faulted. However,
a “chime by zone” option, when programmed, allows only specific zones to chime if they are
faulted when the system is in the chime mode.
Auxiliary Power Output Features
• Provides 12VDC, 600mA maximum (500mA maximum for UL installations). Uses current-
limiting circuitry for protection.
• Interrupts for smoke detector reset if 4-wire smoke detectors are used.
Programming
Programmed options are stored in electrically erasable, nonvolatile EEPROM memory
(information can be reprogrammed at any time and will not be lost in the event of a power
loss).
The system can be uploaded, downloaded, or controlled via an IBM-compatible computer,
COMPASS software, and a
modem specified by ADEMCO.
Keypad programming consists of:
• Data field programming
• Interactive (menu) mode programming.
To program from a keypad, you must connect a 6139 2-line alpha keypad, but it need not stay in
the system.
Communication Formats Supported
•
ADEMCO Low Speed
(Standard or Expanded)
•
Sescoa/
Radionics (Standard or Expanded)
•
ADEMCO
Express
•ADEMCO
Contact ID
Zone Descriptors
You can assign
alpha descriptors to all zones (only when using alpha keypads).
AC Power Supply
Uses
1321/1321CN
, 110VAC plug-in transformer with 16.5VAC, 25VA output, unless
Powerline Carrier devices
(for example,
X10 type) are used, in which case a 4300
Transformer Module
must be used.
Backup Battery
Rechargeable (Sealed Lead Acid) 12VDC, 4AH-17.2AH. Refer to
Section 12: Final Power-
Up
to calculate the actual battery size needed.