VISTA-15/VISTA-15CN Installation and Setup Guide
7–4
Wiring Connections
To wire the Powerline Carrier device to the control panel, perform the following steps:
1. Splice one end of a 3-conductor cable to the wire ends of the 4142TR Cable supplied with
the 4300 Transformer.
2. Connect the 4142TR Cable Plug to the 9-pin connector on the control (see Figure 22.
Summary of Connections diagram for location of the 9-pin connector).
3. Connect the other end of the 3-conductor cable to the 4300 Transformer, as indicated in
the table below and in the diagram that follows.
4300 TRANSFORMER WIRE CONNECTIONS
4300 Terminal To Terminal on Control
1 (AC) 1 (16.5V AC in)
2 (Ground) 25 Earth Ground terminal
3 (AC) 2 (16.5V AC in)
4300 Terminal 4142TR Cable Wire
4 (Sync) RED (Pin 5 of 9-pin connector)
5 (Data) VIOLET (Pin 1 of 9-pin connector)
6 (Com) WHITE (Pin 4 of 9-pin connector)
123456789
9-PIN CONNECTOR
ON CONTROL BOARD
BLACK
BLUE
BROWN
GREEN
RED
WHITE
YELLOW
GRAY
VIOLET
4142TR CABLE
1
2
3
4
56
125 2
AC
Earth
Ground
AC
Sync
Data
Com
4300 TRANSFORMER INTERFACE
TERMINALS
ON CONTROL
BOARD
Figure 15. 4300 Transformer Wiring Connections
Programming Relay Outputs
In the VISTA-15/VISTA-15CN, each device must be programmed as to how to act (ACTION),
when to activate (START), and when to de-activate (STOP). Refer to the programming
procedures for
✱
80 and
✱
81 interactive modes that are provided in Section 13: Mechanics
of Programming, Section 17: Output Device Programming, and Section 18: Zone Lists
for specific programming details.