Section 15 - Data Field Descriptions
15–13
✱
90 EVENT LOGGING 3
0 = no event logging
1 = log Alarm/Alarm Restore
2 = log Trouble/Trouble Restore
4 = log Bypass/Bypass Restore
8 = log Open/Close
x = log combination of events (add value of entries)
Example: To select “Alarm/Alarm Restore” and “Open/Close,” enter 9 (1 key + 8
key); to select all events, enter #15.
The default of 3 = Alarm/Alarm Restore (1) plus Trouble/Trouble Restore (2).
The VISTA-15/VISTA-15CN system can record up to 48 events in a history log.
The types of events to be logged are selectable. At any time, the downloader
operator can then upload the log and view or print out all or selected
categories of the log. The downloader operator can also clear the log.
The display/printout at the Central Station shows the date, time, event, and
description of the occurrences. The time is calculated by an internal clock in
the panel. Note that the time for any events that occur prior to a system
power-down or an entry into the Programming mode cannot be calculated by
the panel. The time then appears on the log as “unknown.”
NOTE: System messages are logged when any nonzero selection is made.
✱
91 OPTION SELECTION (Audio Alarm Verification)
8
0 = not using AAV
4 = an Audio Alarm Verification (AAV) unit is connected to the system
8 = enable Exit Delay Restart (Quick Exit)
12 = both AAV and Exit Delay Restart
UL installations: Must be 0 (AAV disabled).
✱
92 PHONE LINE MONITOR ENABLE
0
0 = not used
1 = local keypad display only when phone line is faulted
2 = local keypad display plus keypad trouble sound when line is faulted; no
automatic timeout
3 = same as “2” above plus Device No. 2 STARTS; if system is armed, external
sounder activates; external sounder is turned off by normal bell timeout,
or by entering Security Code + OFF.
NOTES:
• Option 3 may be used even if a relay unit or Powerline Carrier device is
not connected to the control.
• Device number 2 must either be programmed to be STOPPED in field
✱
80 or STOPPED by entry of Security Code + # + 8 + 2. Field
✱
80
should be set to 0 for STOP.
This feature does not function properly unless the designated earth ground
terminal (25) is physically connected to earth ground. If it is not, you may get
false line-cut indications.