VISTA-128B Installation Instructions
14-2
Access Control of an Entry/Exit Point
The control can send entry and exit requests to the PassPoint ACS utilizing keypads,
hardwired zones, and rf transmitters. A zone is programmed with a response type 27 (Access
Point) and an appropriate input type (console, hardwired, rf).
Using the Alpha Keypad
The following entries at the keypad provide access of a door.
Code + #73
Code + #74 + access point
These entries allow a user to gain access to an access point in the PassPoint system or to
trigger a relay on the control.
Code + #75 + access point + function
This entry requires the installation of the VGM and the PassPoint ACS. The selectable
functions available are Grant, Protect, Bypass. Selecting ‘Grant” will temporarily unlock
a door. Selecting “Protect” will cause the door to unlock only when a valid keypad entry
is received. Selecting “Bypass” will cause the door to be permanently unlocked to allow
continuous access.
Programming the keypad
1. Enter Zone Programming in the #93 Menu Mode.
2. Program the zone with a response type 27 (Access Point).
3. Enter the access point number (00-31) of the door and indicate whether this is an entry
or exit console.
4. Enter the partition number.
5. Enter the input type as CS (09).
6. Enter the keypad ECP address.
See Zone Programming in #93 Menu Mode Programming section for a detailed explanation.
Using an RF Transmitter Zone
An rf button-type transmitter (5804) can be used to provide access or egress for up to 4 doors.
One button will control one door. Also, a button can be used to provide access or egress due
to a panic or duress condition.
An rf transmitter (5816) can be used with a remote switch to provide exit in case of a fire
alarm.
The PIR (5890) can be used to provide exit while preventing entry through a door.
The smoke detector (5808), can be used to provide egress in emergency situations.
Programming the RF Transmitter
1. Enter Zone Programming in the #93 Menu Mode.
2. Program the zone with a response type 27 (Access Point).
3. Enter the access point number (00-31) of the door.
4. Indicate whether rf device is for entry or exit.
5. Enter the partition number
6. Enter the input type: supervised rf (03), unsupervised rf (04), or button rf (05).
7. Enter the loop number.
8. Enroll the serial number.
See Zone Programming in #93 Menu Mode Programming section for a detailed explanation.