Section 29 - Keypad Functions
29-3
Notes:
When using the Global Arm feature, if there are faults in any of the selected partitions,
the system will enter a Summary Mode in which the faulted zones of all of the selected
partitions will be displayed. These faults must be corrected or bypassed (code + BYPASS
+ [#] will attempt to bypass the faults in all of the selected partitions). This Summary
Mode will end in approximately 120 seconds if no keys are pressed.
If, when disarming the system using a Global Disarm, any of the selected partitions has a
condition which would cause the keypad to beep (such as alarm memory or a trouble
condition), the system enter a Summary Mode in which the alarm memory or trouble
conditions of all of the selected partitions will be displayed. This mode will continue until
either approximately 120 seconds elapses or a second disarm occurs which clears the
beeping.
Access Control
The system has the capability to utilize access control by one of 3 methods.
1. One relay may be used for access control in each partition. The relay is programmed in
data field 1*76. To activate this relay, the user enters his User Code + [0]. The relay will
pulse for 2 seconds.
2. For a more powerful method of access control, program input devices (keypads, RF
buttons, hardwired) and output devices (relays) as access points (see the Access Control
section). Up to 32 access point devices (relays) among 8 partitions can be controlled. For
example, if a keypad is programmed as an access input device, then entering [User
Code] + [#73] or [User Code] + [#74] will activate the appropriate access point relays
(see also Zone Programming and Relay Programming in the #93 Menu Mode section).
3.
If a Vista Gateway Module is installed along with the ADEMCO PassPoint Access
Control System, then these same inputs will automatically control the appropriate access
points in the PassPoint ACS. Entering
[User Code]
+
[#75]
will control the state
(protect, bypass, lock) of a door.
Delaying Closing Time
If open/close schedules are used, end users can manually delay closing time by extending the
closing window by 1 or 2 hours. This is useful if a user must stay on the premises later than
usual. The user must have an authority level of Manager or higher.
To extend the closing window, enter [User code] + [#] +82.
Closing Delay ?
Hit 0-2 Hours
Enter the number hours, 1 or 2, by which the end of the closing
window should be extended. Note that the delay is from the
scheduled closing time, not from the current time.
Press [
]
to accept entry and exit this mode. Press [#] to exit
this mode without changes.
The system will send an Access Schedule Change report to the
central station when the closing window is extended (if
programmed).
An extension of the closing window cannot be reduced once it is set. However, a 1-hour delay can
be increased to 2 hours. This is to prevent the user from deleting the delay after the normal window
expires, thereby missing the end of the window.