VISTA-128B Installation Instructions
23-12
Report Code Programming
All report codes are entered using #93 Menu Mode Programming, either through Report Code
Programming, or through the Zone Programming while entering other zone information. In
the VISTA-128B, reports are divided into five categories. These categories represent the
main menu options found in the Report Code Programming. Reports and the categories in
which they are found are as follows:
ALARM CODES RESTR, SUPV. CODES
(for groups of 16 zones)
SYSTEM GROUP #1
Zone Alarm Reports Alarm Restore
Trouble
Trouble Restore
Bypass
Bypass Restore
Closing (arm AWAY)
Opening (disarm)
System Low Battery
Low Battery Restore
AC Loss
AC Restore
Periodic Test
Power
Cancel
Program Tamper
SYSTEM GROUP #2 SYSTEM GROUP #3
Arm STAY
Time Set, Log Reset
Log 50%, 90% Full
Event Log Overflow
Exit Error by Zone
Exit Error by User
Recent Close
Early Open
Early Close
Late Open
Late Close
Failed to Open
Failed to Close
Auto-Arm Failed
Schedule Change
The programming sequence that follows assumes that you will be entering all reports for the
system at one time. In actuality, you may skip from one main menu option to another by
pressing 0 (N) at each main menu option. Main menu options are highlighted in bold text.
To enter report codes, do the following:
Enter Program Mode [Installer Code] + 8 0 0 0. Then press #93. Enter 0 (N) at each main
menu option until the Report Code Programming option is displayed.
REPORT CODE PROG
1 = YES 0 = NO 0
Press 1 (Y) to enter to
Report Code Programming
.