VISTA-128B Installation Instructions
13-2
There are two subscriber ID’s programmed into the LRR: primary and secondary. These
correspond to the two subscriber ID’s programmed into the control for each partition. If a
subscriber ID for a partition is not programmed (disabling reports to that central station
phone number for that partition), the events enabled for the corresponding subscriber ID in
the LRR will not be transmitted.
If the event is to be reported to both phone numbers, dual reporting, then reporting through
the LRR, will be done in an alternating sequence. The first event in the queue will be
transmitted to the primary radio central station. Then this event will be transmitted to the
secondary radio central station. If the event was reported successfully via the control’s
dialer, it will be deleted from the radio’s transmission queue. The control will then proceed to
the next event in the queue.
If split reporting is selected for the VISTA-128B, then the LRR will follow that option. The
radio will send the appropriate reports to the primary and secondary central stations.
Wiring the Long Range Radio
Connect the data in/out terminals and voltage input terminals of the radio to the control’s
keypad connection points, terminals 6, 7, 8, and 9, as shown below.
RED
BLACK
GREEN
YELLOW
6
7
8
9
CONTROL
TERMINALS
7820
Figure 13-1. Wiring Long Range Radio to Keypad Terminals
Programming the Control for the Long Range Radio
The control’s subscriber ID can be passed to the LRR and incorporated into the transmitted
data; or the LRR can transmit the subscriber ID programmed in its own EEPROM, (see the
programming of the Long Range Radio in
Device Programming
in the
#93 Menu Mode
Programming
section).
An option exists to send the reports only via the LRR, bypassing the control’s dialer
completely (field 56).
There is an option to stop transmissions via the LRR if communication via the control’s dialer
to the central station was successful (field 57).
The LRR reporting options are defined by selecting categories of events for each subscriber
ID. Field 58 is for selecting the events for the primary subscriber’s ID; field 59 is for
selecting the events for the secondary subscriber’s ID. The reporting categories are: Alarms,
Troubles, Bypasses, Openings/Closings, System Events, and Tests.
The control can be programmed to transmit these reports by partition.