Section 24 – Scheduling Options
24-19
User Scheduling Menu Mode
The system provides up to 20 "timers" which will be available to the end user for the purpose
of controlling output devices (4204 relay). These timers are comparable to the individual
appliance timers that might be purchased at a department store. The output devices
themselves are programmed into the system by the installer during Relay Programming in
the #93 Menu Mode. The end user needs only to know the output device number and its
alpha descriptor.
The installer may set certain relays to be "restricted" during Relay Programming in the # 93
Menu Mode. These relays may not be controlled by the end user (this prevents the end user
from controlling doors, pumps, bell outputs, etc.)
To enter this mode, the user enters
[Security Code] + # + 83.
Output Timer # ?
01-20, 00=Quit 01
Enter the output timer number to be programmed
(01-20)
.
Press [∗
]
to accept entry and move to the next prompt.
Enter
00
to quit and return to normal operating mode.
06 07:00P 11:45P
PORCH LITE 04
If that timer number has already been programmed, a
summary screen will appear. In this example:
06 = Timer #
07:00PM = Start Time
11:45PM = Stop Time
PORCH LITE = Descriptor for Output Device # 4
04 = Output Device # affected by this timer
Press [∗
]
to continue.
06 ENTER OUTPUT#
PORCH LITE 04
Enter the desired output number
(01-32)
.
As the number is entered, the descriptor for that output device
will be displayed.
Press [∗
]
to continue.
Entering
00
as the output number deletes the timer (Timer 06, in this example) and displays an
output descriptor of "None." Output devices are programmed via #93 Menu Mode.
06 ON TIME ?
07:00 PM
The cursor will be positioned on the tens of hours digit of the
ON time. Enter the desired hour.
Press [∗
]
to move to the minutes field. The minutes are entered
in the same manner.
The AM/PM indication is toggled by hitting any key in the
0-9
range while the cursor is under the AM/PM position.
Press [∗
]
to continue.