Section 23 - #93 Menu Mode Programming
23-5
↓ Zone Number
010 ZONE RESPONSE
Perimeter 03
Zone Type 03 entry shown
Each zone must be assigned a zone type, which defines the way
in which the system responds to faults in that zone. Refer to
the
Zone Type Definitions
section for detailed definitions of
each zone type. Enter the zone type desired (or change it, if
necessary). Available zone types are listed below.
00 = Assign for Unused Zones 10 = Interior Delay, Burglary
01 = Entry/Exit #1, Burglary 20 = Arm–STAY†
02 = Entry/Exit #2, Burglary 21 = Arm AWAY†
03 = Perimeter, Burglary 22 = Disarm†
04 = Interior Follower, Burglary 23 = No Alarm Response
05 = Trouble Day/Alarm Night (e.g., Relay
06 = 24 Hr. Silent Alarm activation)
07 = 24 Hr. Audible Alarm 27 = Access Point
08 = 24 Hr. Auxiliary 28 = MLB Supervision
09 = Fire Without Verification (if VGM installed)
† These are special zone types used with 5800 Series Wireless
Pushbutton Units which will result in arming the system in the
STAY or AWAY mode, or disarming of the system, depending
on the selection made.
Press [*] to continue.
010 ACCESS POINT
(00-31) 01
If response type 27 was selected, this prompt will be displayed.
Enter the access point to be controlled by the input type
(00-
31)
.
010 ENTRY OR EXIT
0
Select whether the access point is an entry or exit point.
0
= entry
1
= exit
010 PARTITION
2
Enter the partition number
(1–8)
you are assigning this zone
to.
Press [*] to continue.
010 REPORT CODE
1st 03 2nd 12 3C
Enter the report code. The report code consists of 2
hexadecimal digits, each in turn consisting of 2 numerical
digits. For example, for a report code of "3C", enter
03
for "3"
and
12
for "C."
(Refer to
System Communication
section for more information
about report codes and report code formats.)
Press [*] to continue.