Vista 120 Training Guide 41
6.2 5882 Wireless Expansion
Training Module
There are three (3) models of 5882:
Ø 5882L will permit up eight (8) additional RF zones.
Ø 5882M will permit up to sixteen (16) additional RF zones.
Ø 5882H will permit up to one hundred & twenty eight (128) additional RF zones.
Note: Two identical receivers can be used to provide either a greater area of coverage, or
to provide redundant protection.
Zone 64 cannot be programmed for a Wireless zone.
If using two (2) receivers
Each unit must be set to a different device address between 01-07.
Using two (2) receivers DOES NOT increase the number of transmitters the system can
support.
Both receivers must be of the same model.
Receivers should be mounted at least 3 Metres from the Control Panel.
TO INSTALL WIRELESS RECEIVERS
Connect 5882 via the flying lead supplied to terminals 6 (RED), 7 (BLACK), 8 (GREEN) and 9
(YELLOW) of the Vista 120a.
Set 5882’s DIP switch to an unused device address between 01-07.
Use 6139 console to enter programming mode: installer code + 8 0 0 0
Enter *94 to move to 2
nd
Level of Programming
Program 1*32 “Receiver Type”, enter 2 (for 5881/5882).
Enter *99 to return to 1
st
level of programming
Press # 9 3 to enter Menu Mode.
Press 0 (NO) until “Device Prog?” is displayed, then press 1 (YES).
• Enter the two digit Address Number (01 – 07), as set on the 5882’s Dip Switches
• Press * to move to Device Type
• Enter a Device Type “3” for RF Expander
• Press * to move to RF Expander House ID
If not using a ny RF keypads (5804BD, 5827BD or 5827, press * to continue.
If one, or more than one RF keypads are to be used, enter the two (2) digit House ID (00-31)
as determined by sniffer mode.
If two 5882’s are to be used, follow the same procedure until all outp ut devices have been
programmed, enter 0 0 * to exit “Device Prog?”.
Console will display “Quit Menu Mode?”, enter 1 (Yes) or 0 (No) if more devices need to be
programmed.