Vista 120 Training Guide
22
VISTA 120 PROGRAMMING FORM
Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these
fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
*59 SELECTION OF CONTACT ID
MESSAGE DATA ON KEYPAD Alarms Troubles Bypasses Open/ System Test
BUS FOR SUBSCRIBER ID#2 [0][0][0][0][0][0] Close Conditions Reports
1=Yes; 0=No
*60 VERIFIED ALARM REPORT
[0]
ENABLE 1= Yes (Swedish requirement)
0= No
*61 ROBOFON VERSION OF
[0]
CONTACT ID 0= Yes (Swedish requirement),
0= No
*79 ZONE TYPE RESTORE ENABLES [0]
FOR ZONE TYPES 1-8 1 2 3 4 5 6 7 8
1=enable; 0=disable
*80 ZONE TYPE RESTORE ENABLES [0]
FOR TYPES 9/10 9 10
1=enable; 0=disable
*83 FIRST TEST REPORT TIME | | |
[Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-59;
00 in all boxes=instant (Day 01= Monday)
*84 INTERMITTENT SENSOR Partition-Specific
SUPPRESSION
*85 ENABLE DIALLER REPORTS [0] Partition-Specific
FOR PANICS & DURESS
*86 REPORT/LOG ZONE TYPE 23 [0] 1=yes; 0=no
*87 ENTRY WARNING Partition-Specific
*88 BURG. ALARM COMM. DELAY Partition-Specific
*89 RESTORE REPORT TIMING [0] 0=Instant; 1=After bell timeout if zone is restored; 2=when system is
disarmed.
*90 SECONDARY SUBS. ACCT.# Partition-Specific
1*00 CONTACT ID REPORTING IN
[0]
ASCII THROUGH PRINTER PORT 1= Yes 0= No, event log usage
1*01 ASCII CONTACT ID REPORTING
[0]
WITH OR WITHOUT ACK 1= ACK not required 0= ACK required
1*02 ASCII CONTACT ID BAUD RATE
[0] 0= 1200 1= 2400 2= 4800
1*05 BYPASS ENABLE FOR FIRE ZONES [0]
1=yes, allow bypass of fire zones; 0= fire zones cannot be bypassed
1*06 SUPPRESS ALL KEYPAD DISPLAYS
[0]
WHEN SYSTEM IS ARMED 0= Yes; 0= No