Vista 120 Training Guide
20
VISTA 120 PROGRAMMING FORM
Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these
fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
*24 IGNORE EXPANSION [0]
ZONE TAMPER 1=Ignore; 0=Enable tamper for RF and RPMs.
*25 BURG.TRIGGER FOR [1]
RESPONSE TYPE 8 1=enable; 0=disable
*26 INTELLIGENT TEST REPORTING [0] 1=yes, (no report sent if any other report was recently sent); 0=no.
*27 TEST REPORT INTERVAL | | [024]
001-999; 000=no report; Enter interval in hours.
*28 POWER UP IN PREVIOUS STATE [1] 1=yes; 0=no
*29 QUICK ARM Partition-Specific
*30 MULTIFREQUENCY OR [0] ( 1 = Recommended )
PULSE DIAL 1=Multifrequency (DTMF); 0=Pulse Dial
*31 PABX ACCESS CODE | | | |
Enter 00-09; B-F (11-15)
*32 PRIMARY SUBS. ACCT # Partit ion-Specific
*33 PRIMARY PHONE NUMBER
Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause
*34 SECONDARY PHONE NUMBER
Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause
*35 DOWNLOAD PHONE No.
Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause
*36 DOWNLOAD ID No. | | | | | | | |
Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]
*37 DOWNLOAD COMMAND ENABLES 0 [1]
Dialler System Restrict Remote Remote Remote Upload Download
Shutdwn Shutdwn Access Bypass Disarm Arm Prog Prog
See field 1*53 for Callback disable option; 1=enable; 0=disable
Restrict Download Access When Armed: Can only arm unarmed partitions,
upload the programme/ event log, command relays, and request status
*38 PREVENT ZONE XXX BYPASS Partition-Specific
*39 ENABLE OPEN/CLOSE REPORT Partition-Specific
FOR INSTALLER CODE
*40 OPEN/CLOSE REPORT
[0]
FOR KEYSWITCH 1=enable; 0=disable
*41 NORMALLY CLOSED or EOLR
[1]
(Zones 2-8) 1=N.C. loops; 0=EOLR supervision
*42 SUPPRESS FIRE ALARM RELAY 1= suppress fire alarm relay on 4204/Powerline Carrier Device relays
0= 4204/Powerline Carrier Device fire alarm relay activates on fire alarms