VISTA 120 PROGRAMMING FORM
Some fields are programmed for each partition (shown as shaded fields). See the PARTITION-SPECIFIC section for programming these
fields. Standard default (*97) values are shown in brackets [ ], otherwise default = 0.
1*28 RF TX LOW BATTERY SOUND [0] 1=immediate; 0=when disarmed
1*29 RF TX LOW BATTERY REPORT ENABLE [0] 1=enable; 0=disable
1*30 RF RCVR CHECK-IN INTERVAL | [06] 02-15 times 2 hours; 00 disables supervision
1*31 RF TRANSMITTER | [12]
CHECK-IN INTERVAL 02-15 times 2 hours; 00 disables transmitter supervision
1*32 RF RECEIVER TYPE [0] 1=4281; 2=5881/5882
1*33 MULTIFREQUENCY with [0]
PULSE DIAL BACKUP 1=enable; 0=disable
1*34 COMM. SPLIT REPORT SELECTION [0]
0=no; 1=alarms and alarm restores primary, others secondary; 2=open/close, test secondary, others primary; See T51 for
comments if using with dual reporting.
1*35 LOW BATTERY TEST INTERVAL [0]
1 = 1.5 second test every 50 seconds
0 = 13 second test every 4 minutes
1*36 CPU FAIL TRIGGER OUTPUT [0]
1 = yes, Output trigger 2 on J7 to be CPU fail output, overriding any
other selection for Output 2 (CENELEC requirement)
0 = no, normal use for Output 2
1*37 TLM INPUT ON ZONE 9 [0]
1 = yes, telephone line fault monitor output to be fed into zone 9
0 = no, normal use for zone 9
1*38 USER RESET OF TAMPER ALARMS [0] ( 1 = Recommended )
INSTEAD OF INSTALLER ONLY RESET 1 = yes 0 = no
1*39 USER BYPASS OF TAMPER [0] ( 1 = Recommended )
FAULTS INSTEAD OF 1 = yes
INSTALLER ONLY BYPASS 0 = no
1*40 MAX. NUMBER OF ZONES THAT | [00]
CAN BYPASSED PER PARTITION 01-15, 00 = no restriction
(partition-specific)
1*41 BYPASS/UNBYPASS ZONES [0]
WHEN ARMED 1=Yes; 0=No.
1*42 CALL WAITING DEFEAT [0]
1=Yes; 0=No.
1*43 PERM. KEYPAD BACKLIGHT Partition-Specific
1*44 WIRELESS KEYPAD [1] (Locks out keypad after 20 key sequential key presses)
TAMPER DETECT ENABLE 1=enable; 0=disable.
1*45 EXIT DELAY SOUNDING Partition-Specific
1*46 AUXILIARY OUTPUT MODE [0]
0 = ground start output; 1 = open/close trigger; 2 = keypad-like
sounding 3 = AAV module is being used