Automatic Refresh: The system automatically updates the status of all Time-Driven Events upon any of the following
occurrences:
Changing of the time or date via #63 mode
Exiting #80 Scheduling Menu mode
Exiting Program mode
After a disconnect from the downloader
On a power-up
At Daylight Saving Time adjustment.
Below is a list of the "Action" codes (desired actions) used when programming time-driven events. Note that these codes are
independent of the "relay codes" programmed during the #93 Menu ModeOutput Programming mode. If using Time Driven
Events, the following menu items must first be programmed using #93 Menu Mode - Output Programming:
Enter Relay No. (reference identification number)
Relay Group (if applicable)
Restriction
Relay Type (V-Plex, 4204/4204CF, FSA, or X-10)
Zone No. (V-Plex)
ECP Address (4204/4204CF or FSA)
Relay No. (4204/4204CF)
LED No. (FSA)
House Code (X-10)
Unit Code (X-10)
Relay commands:
Action Specifier for commands 01-05 is Relay No.; Action Specifier for commands 06-10 is Relay Group No.
01 = Relay On 02 = Relay Off
03 = Relay Close for 2 seconds 04 = Relay Close XX minutes (field 1*74)
05 = Relay Close YY seconds (field 1*75) 06 = Relay Group On
07 = Relay Group Off 08 = Relay Group Close for 2 seconds
09 = Relay Group Close XX minutes (field 1*74) 10 = Relay Group Close YY seconds (field 1*75)
Arm/Disarm commands:
Action Specifier for commands 20-24 is Partition(s). Activation times 1 (Beginning), 2 (End), 3 (During), 5 (Random Start), 6
(Random End), 7 (Random During) are the only valid choices for auto-arming and disarming functions.
20 = Arm-Stay 21 = Arm Away
22 = Disarm 23 = Force Arm Stay (Auto-bypass faulted zns)
24 = Force Arm Away (Auto-bypass faulted zns) 25 = Arm Instant
26 = Arm Maximum
Bypass commands:
Action Specifier for commands 30-31 is Zone List #, Activation times 1 (Beginning), 2 (End), 3 (During), 5 (Random Start), 6
(Random End), 7 (Random During) are the only valid choices for bypass commands.
30 = Auto bypass - Zone list 31 = Auto unbypass - Zone list
Open/Close Windows:
Action Specifier for commands 40-41 is Partition(s), and for 42 is Access Group. Activation time 3 (During), 7 (Random
During) are the only valid choices for these commands.
40 = Enable Opening Window 41 = Enable Closing Window 42 = Enable Access Window
Access Control Commands
Action Specifier for commands 55-60 is Access Point, for 61-66 is Group, for 67-72 is Partition, and for 73-74 is Trigger.
55 = Access Point Grant 56 = Access Point Grant with Override
57 = Access Point Protect 58 = Access Point Bypass
59 = Access Point Lock 60 = Access Point Exit
61 = Access Point Group Grant 62 = Access Point Group Grant with Override
63 = Access Point Group Protect 64 = Access Point Group Bypass
65 = Access Point Group Lock 66 = Access Point Group Exit
67 = Access Point Partition Grant 68 = Access Point Partition Grant with Override
69 = Access Point Protect by Partition 70 = Access Point Bypass by Partition
71 = Access Point Lock by Partition 72 = Access Point Exit by Partition
73 = Access Point Trigger On 74 = Access Point Trigger Off
Additional Commands
Action Specifier for command 78 is Group.
78 = Access Point Group Disable