– 21 –
PROMPT
EXPLANATION
Zn ZT P RC In L
010 03 1 10 RF
-
Enter all zone information except for Loop number, or press “C” to copy the zone information on this screen
from the last saved zone (including Loop).
ZT = Zone Type
P = Partition
RC = Report Code
In = Input Device Type
L = Loop number to which the sensor is connected.
NOTE: Pressing the [C] copies the zone information from the last saved zone, which includes the
input type. Verify this information is correct for this zone.
On this screen:
Use the [A] key to move to the right.
Use the [B] key to move to left and to back up to “ZT” field.
Press [] to accept the existing or newly-entered zone information.
ZN B M V A C E AD
010 1 0 1 1 01
Enter the remainder of the zone’s information, or press the [C] key to copy the zone attributes on this screen
from the last saved zone.
B = Not Applicable
M = Not Applicable
V = V-plex Relay? (only used if “In” = 6)
AC = Access Point (only used if ZT = 27, 29 or In = 6, 11, 12, 13)
E = Entry or Exit? (only used if ZT = 27)
AD = Address (only used if “In” = 9 or 10)
If “In” = 9, enter the Device Address
If “In” = 10, enter the PassPoint Zone Number
NOTE: Pressing the [C] copies the zone attributes from the last saved zone. Verify the attributes for
this zone are correct.
On this screen:
Use the [A] key to move to the right.
Use the [B] key to move to left and to back up to “V” field.
Press [] to accept existing information.
010 INPUT S/N: L
A XXX-XXXX
-
If you entered RM, RF, BR, UR or SL for the Input Type, this screen displays. Otherwise the summary
screen for the next zone displays.
Enter the 7-digit serial number, using one of the following methods:
a. Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and
release the button, wait approximately 4 seconds, then press and release the button a second time.
OR
b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the alpha keypad.
Then press the [] key, the cursor will move to the “L” position. You can edit the loop number, if
necessary. When the loop number is acceptable, press [].
OR
c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several
input loops).
Remember, you can use the [A] key to move to the right or the [B] key to move to the left.
You can also use the [#] key to back up without saving.
010 INPUT S/N: L
A022-4064 1
Press [] to accept the serial number and advance to the “L” position (if method “a” or “c” was used), then
enter the loop number.
If necessary, press the [#] key to back up without saving, and re-enter or edit the serial number before
pressing [] to save
The system checks for a duplicate. If a duplicate serial/loop number combination is found, the keypad will
emit a single long beep, and display the serial number along with a “?” for the loop number, allowing you to
re-enter the correct loop number.
010 INPUT S/N: L
A000-0000 1
To Delete an Existing Serial Number, enter “0“ in the loop number field. The serial number will change to
“0”s.
If “0” was entered in error, simply re-enter the loop number or press [#], and the serial number will return to