Optional Long Range Radio
Allows all messages that have been programmed to go to the primary
telephone number to be reported additionally to a 7720PLUS or 7820 radio.
Check availability of these models.
Built-in Telephone Line Monitoring Option
The telephone line voltage can be monitored to supervise the phone line
connection. The panel must be connected to a proper earth ground or
you will get a false line cut indication if this feature is enabled.
The loss of the line can optionally cause a local display, or a display and
trouble sound.
Event Logging
¥ Event Logging feature keeps a record of selected events in a history log
(up to 48 events). All control and readout from the log is done via Ademco
V-Link software only.
Alarm Output
¥ Provides a 12VDC, 2 AMP output that can drive the compatible sounders
listed in the EXTERNAL SOUNDERS section (assumes a fully charged battery
is connected)
.
Steady output for Burglary/Panic, or temporal pulse output (3 pulses –
pause – 3 pulses – pause – 3 pulses. . .) for Fire
Uses current limiting circuitry for protection
Auxiliary Power Output
Provides 12VDC, 600 mA maximum. Uses current limiting circuitry for
protection.
This output interrupts for smoke detector reset if 4-wire smoke detectors
are used.
Programming
Programmed options are stored in electrically erasable, non-volatile
EEROM memory (information can be reprogrammed at any time and will
not be lost in the event of a power loss).
The system can be uploaded, downloaded, or controlled via an IBM
compatible computer, V-Link software and a HAYES modem specified by
Ademco.
Keypad programming consists of:
Data field programming
Interactive (menu) mode programming
For programming from a keypad, a 5137AD or 6139 2-line Alpha keypad must
be connected to partition 1 (but need not necessarily stay in the system).
Communication Formats Supported
Ademco Low Speed (Standard or Expanded)
Sescoa/Radionics (Standard or Expanded)
Ademco Express
Ademco Contact ID
Zone Descriptors
You can assign Alpha descriptors to all zones (useful only when using Alpha
keypads and/or the 4285 Phone Module).
AC Power Supply
Uses 1321, 110VAC plug-in transformer with 16.5VAC 25VA output, unless
Powerline Carrier devices (ex. X-10 type) are used, in which case a 4300
transformer module must be used.
Back-Up Battery
Rechargeable (Gel type) 12VDC, 4AH minimum.