ADEMCO VISTA-128B Betriebsanweisung

Stöbern Sie online oder laden Sie Betriebsanweisung nach Sicherheitszugriffskontrollsysteme ADEMCO VISTA-128B herunter. ADEMCO VISTA-128B User guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 80
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
K5895V5 4/09 Rev C
V
V
I
I
S
S
T
T
A
A
-
-
1
1
2
2
8
8
B
B
P
P
/
/
V
V
I
I
S
S
T
T
A
A
-
-
2
2
5
5
0
0
B
B
P
P
/
/
V
V
I
I
S
S
T
T
A
A
-
-
1
1
2
2
8
8
S
S
I
I
A
A
E
E
n
n
h
h
a
a
n
n
c
c
e
e
d
d
C
C
o
o
m
m
m
m
e
e
r
r
c
c
i
i
a
a
l
l
B
B
u
u
r
r
g
g
l
l
a
a
r
r
y
y
P
P
a
a
r
r
t
t
i
i
t
t
i
i
o
o
n
n
e
e
d
d
S
S
e
e
c
c
u
u
r
r
i
i
t
t
y
y
S
S
y
y
s
s
t
t
e
e
m
m
W
W
i
i
t
t
h
h
S
S
c
c
h
h
e
e
d
d
u
u
l
l
i
i
n
n
g
g
U
U
s
s
e
e
r
r
G
G
u
u
i
i
d
d
e
e
Seitenansicht 0
1 2 3 4 5 6 ... 79 80

Inhaltsverzeichnis

Seite 1

K5895V5 4/09 Rev C VVIISSTTAA--112288BBPP//VVIISSTTAA--225500BBPP// VVIISSTTAA--112288SSIIAA EEnnhhaanncceedd CCoommmmeerrcciiaall BBuurrggl

Seite 2

– 10 – About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during y

Seite 3 - TABLE OF CONTENTS

– 11 – Functions of the Keypad 1OFF4MAX7INSTANTREADY2AWAY5TEST8CODE03STAY6BYPASS#ARMEDREADY6160-00-002-V19CHIMEABCDSPEAKERLCDDISPLAYFUNCTIONKEYSLEDS

Seite 4

– 12 – Functions of the Keypad (cont’d)ALPHA DISPLAY WINDOW: A 2-line, 32-character Liquid Crystal Display (LCD) that displays protection point ide

Seite 5 - System Overview

–13 – Functions of the Keypad (cont’d) 9 CHIME : Turns on & off the CHIME mode. When on, any entry through a protected delay or perimeter zo

Seite 6 - System Overview (cont’d)

– 14 – Entry/Exit Delays General Information Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm

Seite 7

– 15 – Security Codes and Authority Levels General Information At the time of installation, you were assigned an authority level and a personal four

Seite 8

– 16 – Security Codes and Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. Dep

Seite 9

– 17 – Security Codes and Authority Levels (cont’d) General Rules on Authority Levels and Changes • A user may not delete or change the user code o

Seite 10 - About The Keypads

– 18 – Security Codes and Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function they

Seite 11 - Functions of the Keypad

– 19 – Security Codes and Authority Levels (cont’d) MULTI-ACCESS ? 0 = NO , 1 = YES If you as a user have access to other partitions, the keypad wil

Seite 12

– 2 – Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. You

Seite 13

– 20 – Security Codes and Authority Levels (cont’d) PART. 1 A0* WHSE USER 003 AUTH=3G. When all partitions have been displayed, the keypad will sc

Seite 14 - Entry/Exit Delays

– 21 – Security Codes and Authority Levels (cont’d) To Delete a User CODE 1. Enter Master or Manager code and press the 8 key + user numb

Seite 15 - Quick Arming

– 22 – Accessing Other Partitions To Access another Partition Each keypad is assigned a default partition for display purposes, and will show only t

Seite 16 - Authority Levels

– 23 – Accessing Other Partitions (cont’d) Global Arming Notes: • When performing a Global Arm, if there are faults in any of the selected partitio

Seite 17 - To Exit User Edit Mode

– 24 – Accessing Other Partitions (cont’d) The following is an example of what would be displayed for a fault condition on Zone 002 (Loading Dock Wi

Seite 18 - To Add a User

– 25 – Accessing Other Partitions (cont’d) Common Lobby Operation When an installation consists of a partition that is shared by users of other part

Seite 19

– 26 – Accessing Other Partitions (cont’d) How User Codes Affect the Common Lobby Codes with “Global” Arming If your code is given “global arming” w

Seite 20 - To Change a User's Code

– 27 – Accessing Other Panels If the user is authorized, a keypad in one panel can be used to perform system functions in other panels by using one

Seite 21 - To Delete a User

– 28 – Accessing Other Panels (cont’d) Multi-Partition Multi-Panel Mode To access the multi-partition multi panel mode, perform the following steps:

Seite 22 - Accessing Other Partitions

– 29 – Accessing Other Panels (cont’d) NOTES: When performing any of the arming commands, if there are faults in any of the partitions, none of the

Seite 23 - Master Keypad Operation

– 3 – TABLE OF CONTENTS SYSTEM OVERVIEW ...5 General ...5 A Part

Seite 24

– 30 – Accessing Other Panels (cont’d) Press 0 to exit mode. After a few seconds, the keypad displays the status of the original partition of the

Seite 25 - Common Lobby Operation

– 31 – Checking For Open Zones Using the ✳✳✳✳ READY Key Before arming your system, all protected doors, windows and other protection zones must b

Seite 26

– 32 – Displaying All Zone Descriptors Using the ✳✳✳✳ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed i

Seite 27 - Accessing Other Panels

– 33 – Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally

Seite 28

– 34 – Bypassing Protection Zones (cont’d) 2. BYPASS 007 FRONT UPSTAIRS BEDROOM Typical bypass message In a few moments, all open zones will be dis

Seite 29 - Multi-Panel View Mode

– 35 – Bypassing Protection Zones (cont’d) To use the Group Bypass feature: BYPASS 1. Enter your security code and press 6 then press ✳

Seite 30

– 36 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use

Seite 31 - Checking For Open Zones

– 37 – Arming Perimeter Only (With Entry Delay ON) (cont’d) Auto-STAY Arming Auto-stay allows the system to automatically bypass certain zones if up

Seite 32 - ✳ READY Key

– 38 – Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Important: If you are using a Symphony (Advanced User Interface), NI

Seite 33 - Bypassing Protection Zones

– 39 – Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in

Seite 34 - Group Bypass

– 4 – Arming ...43 Disarming ... 43 CHIME MODE...

Seite 35 - Typical bypass message

– 40 – Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods o

Seite 36 - Arming Perimeter Only

– 41 – Quick Exit Using the # + 9 Keys The Quick Exit feature allows you to exit the armed partition without having to disarm and then rearm

Seite 37

– 42 – Disarming and Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See

Seite 38

– 43 – Using the Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light

Seite 39 - Arming All Protection

– 44 – Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mod

Seite 40

– 45 – Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their

Seite 41 - Quick Exit

– 46 – Panic Keys (For Manually Activating Silent and/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key co

Seite 42 - Memory of Alarm

– 47 – Speed Key (Macros) General Information The “A”, “B”, “C”, and/or “D” keys can be used to activate a string of commands up to 32 keystrokes ea

Seite 43 - Using the Keyswitch

– 48 – Speed Key (Macros) (cont’d) Executing To execute a Speed Key sequence, do the following: If a lettered key, A-B-C has been assigned as a Spee

Seite 44 - Chime Mode

– 49 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momenta

Seite 45

– 5 – System Overview General Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategicall

Seite 46 - Panic Keys

– 50 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by us

Seite 47 - Speed Key (Macros)

– 51 – Using Schedules Delaying the Closing Time Your system's programmed schedules may automatically arm the system at a predetermined time. I

Seite 48 - Speed Key (Macros) (cont’d)

– 52 – Using Schedules (cont’d) Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary sc

Seite 49 - Access Door Control

– 53 – Using Schedules (cont’d) DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the te

Seite 50 - Using #70 Relay Menu Mode

– 54 – Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which t

Seite 51 - Using Schedules

– 55 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the d

Seite 52 - Using Schedules (cont’d)

– 56 – Programming Device Timers (cont’d) Randomize Output Device Times Devices in your system may be set for a random schedule, whereby they will t

Seite 53

– 57 – Using #77 Instant Activation Mode The #77 Instant Activation Mode is used to activate outputs, bypass zones, etc. immediately upon exiting th

Seite 54 - Programming Device Timers

– 58 – Using #77 Instant Activation Mode (cont’d) Bypass Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for

Seite 55

– 59 – Using #77 Instant Activation Mode (cont’d) Additional Commands Action Code Action Specifier 77 Access Point Group Enable Group # 78 Access

Seite 56

– 6 – System Overview (cont’d) A Partitioned System Simply stated, a partitioned system shares one physical alarm system among different users, each

Seite 57

– 60 – Event Log Procedures General Information The system has the ability to record various events in a history log wherein each event is recorded

Seite 58

– 61 – Event Log Procedures (continued) ALARM EVENT LOG Displays time and date for zones that has either caused an alarm or has been restored in the

Seite 59

– 62 – Testing the System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, which allows each protecti

Seite 60 - Event Log Procedures

– 63 – Fire Alarm System Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency,

Seite 61 - Setting the Time and Date

– 64 – Trouble Conditions Typical Trouble Displays The word CHECK or TRBL on the Keypad's display, accompanied by a rapid "beeping"

Seite 62 - Testing the System

– 65 – Trouble Conditions (cont’d) • A display of "SYSTEM LO BAT", accompanied by a once per minute "beeping" at the Keypad in

Seite 63 - Fire Alarm System

– 66 – Recommendations for Proper Protection The following recommendations for the location of fire and burglary detection devices help provide prop

Seite 64 - Trouble Conditions

– 67 – Recommendations for Proper Protection (cont’d) In addition, we recommend the following:  Install a smoke detector inside every bedroom wher

Seite 65 - Trouble Conditions (cont’d)

– 68 – Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the Natio

Seite 66

– 69 – Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possib

Seite 67

– 7 – System Overview (cont’d) Burglary Protection The burglary protection portion of your system must be turned on or "armed" before it w

Seite 68 - Emergency Evacuation

– 70 – Maintaining Your System (cont’d) Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing a

Seite 69 - Maintaining Your System

– 71 – Quick Guide to System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. To view faulted zones when is system not ready Display

Seite 70 - Routine Care

– 72 – Quick Guide to System Functions (cont’d) FUNCTION PROCEDURE COMMENTS Delete a User Enter master/manager code. Press CODE [8]. Enter user n

Seite 71

– 73 – Summary of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is dis

Seite 72

– 74 – FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the I

Seite 73 - (Alpha Display Keypads)

– 75 – “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this e

Seite 74

– 76 – CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment

Seite 75

– 77 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protect

Seite 76

– 78 – Index #70 command... 50 4286 VIP module ... 9, 50 AC Loss ...

Seite 77 - WARNING!

– 79 – Manager ... 16 Master ... 16 Maste

Seite 78

– 8 – System Overview (cont’d) Memory of Alarm When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the prob

Seite 79

ÊK5895V5*Š K5895V5 4/09 Rev C TWO YEAR LIMITED WARRANTY Honeywell International Inc., acting through its Security & Communications business (

Seite 80 - ÊK5895V5*Š

– 9 – System Overview (cont’d) partition, or until 2 minutes has elapsed with no keypad activity. Entering your security code, pressing [✳] followed

Kommentare zu diesen Handbüchern