Panic Keys There are three panic key pairs or (on some keypads) lettered keys that, if
programmed, can be used to manually initiate alarms and send a report to the
central station.
Each can be individually programmed for 24-hour Silent, Audible, Personal or
Fire Emergency responses. The panic function is activated when both keys of the
appropriate key pair are pressed at the same time, or the appropriate lettered key
is pressed for at least 2 seconds.
The panic functions are identified by the system as follows:
ÊÊÊÊÊÊKeys Displayed as Zone
[1] & [
*
], or [A] 95
[
*
] & [#], or [B] 99
[3] & [#], or [C] 96
Notes:
• Keys [A], [B], [C] are not on all
keypads.
• Key [D], if present, is not active here.
Important: For the Silent Panic functions to be of practical value, the system
must be connected to a central station.
Relay/Powerline Carrier
Devices
(if used)
If relay outputs (via a 4204, or 4229), or Powerline Carrier devices are used, two
keypad entries available to the user are included. They can manually activate or
deactivate the device(s) for starting or stopping some action, such as turning
lights on or off, etc.
These keypad entries are:
Security Code + [#] + [7] + Device # activates (starts) that device.
Security Code + [#] + [8] + Device # de-activates (stops) that device.
4285 Phone Module
(if used)
Refer to the separate instructions supplied with the Phone Module for information
concerning its operating procedures.
Note: The Phone Module cannot be used to add user codes in this system.
User codes must be added by using a wired keypad.
Exit Error Alarm
Displays
(if programmed)
• A display of "CANCELED ALARM" or "CA" and a zone indication will
appear if an exit or interior zone contained a fault during closing at the time the
exit delay ended (e.g., exit door left open), but the system was disarmed
during the entry delay time. The alarm sounder and keypad sound
continuously, but stop when the system is disarmed. No message will be
transmitted to the central station.
• A display of "EXIT ALARM" or "EA" and a zone indication will appear if an
exit or interior zone contained a fault during closing at the time the exit delay
ended, but the system was NOT disarmed during the entry delay time.
The alarm sounder and keypad sound continuously until the system is
disarmed (or timeout occurs). An "exit alarm" message is sent to the central
station.
• The "EXIT ALARM" display, etc. will also result if an alarm from an exit or
interior zone occurs within two minutes after the end of an exit delay.
In any of the above cases, use a second OFF sequence (code plus OFF key) to
clear the display.