ADEMCO Vista-50 Bedienungsanleitung Seite 118

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 196
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 117
– 106
2*00 NUMBER OF PARTITIONS
Enter the number of partitions (1-8) to be used in the system.
2*01 DAYLIGHT SAVINGS TIME | |
START/END MONTH
Enter the months 00-12 in which daylight savings time starts and ends.
Enter 00, 00 if daylight savings time does not apply to the user's region.
Standard setting for U.S. is 04,10.
2*02 DAYLIGHT SAVINGS TIME | |
START/END WEEKEND
Enter the start and end weekends for daylight savings time as follows:
01=first; 02=second; 03=third; 04=fourth; 05=last; 06=next to last;
07=third from last. Standard setting for U.S. is 01,05.
2*05 AUTO-ARM DELAY (partition-specific) |
Enter the time between the end of the arming window and the start of
auto arm warning time in values of 01-14 times 4 minutes. Enter 00 if no
delay is desired. Enter 15 if auto arming is not desired.
2*06 AUTO-ARM WARNING PERIOD (partition-specific) |
Enter the time 01-15 in one minute increments during which the user is
warned by a keypad sounding and display to exit the premises prior to
auto arming of the system.
2*07 AUTO-DISARM DELAY (partition-specific) |
Enter the time between the end of the disarming window and the start of
auto disarming of the system in values of 01-14 times 4 minutes. Enter
00 if no delay is desired. Enter 15 if auto disarming is not desired.
2*08 ENABLE FORCE ARM FOR AUTO-ARM
(partition-specific)
Enter 1 if the system should automatically bypass any faulted zones
when it attempts to auto arm. Otherwise enter 0.
2*09 OPEN/CLOSE REPORTS BY EXCEPTION
(partition-specific)
Enter 1 if it is desired that open/close reports be sent only if the
openings/closings occur outside the arm and disarm windows. Open
reports will also be suppressed during the closing window in order to
prevent false alarms if the user arms the system, then reenters the
premises to retrieve a forgotten item. Note that openings and closings
are still recorded in the event log. Enter 0 if exception reporting is not
desired. Note: This field must be set to 1 if late/early opening, late/early
closing, and no opening/closing reports are to be sent (2*13, 2*14).
2*10 ALLOW DISARMING ONLY DURING ARM/DISARM
WINDOWS (partition-specific)
Enter 1 if disarming of the system should be allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to
"1"). Note that this applies only to operator level users. Installer, Master
and manager level users can disarm the system at any time. Enter 0 if
disarming can occur at any time.
0=disable for displayed partition; 1=enable for displayed partition