1. Fully explain the operation of the System to the user by going over
spaces provided m the User’s Manual, record the Entry and Exil Delay
each of its functions as well as the User’s Manual supplied.
times, and those functions that have been programmed into the availa-
2. In particular, explain the operalion of each zone (entry/exit, perimeter,
ble pairs of “Emergency” keys (* and #, 1 and *, 3 and #).
interior, fire, etc.). Be sure the user understands how to operate any
3. Make sure the user understands the importance of testing the system
Emergency feature(s) programmed into the System. Important In the
at least weekly, following the procedure provided in the User’s Manual,
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing bytheuser
are vital to continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance
program to the user as well as acquainting the user with the proper operation and limitations of the
alarm system and its component parts. Recommendations must be included for a specific program of
frequent testing (at least weekly) to insure the system’s proper operation at all times.
The system will store up to 10 days worth of alarm and trouble messages
for display to service personnel w!th the following procedure:
Enter” Security Code plus O
The system’s alarm memory retains all events for a period of 10 days,
starting with the iirst event that occurs. Upon expiration of the 10-day
period, all history IS automatically erased and the alarm memory wdl
reset, However, the 10-day cycle will start again only when the next
event occwa.
Recall by service personnel (using the entry indicated above) w(II display
all events that have occurred from the start of the 10-day cycle to the
time of recall (recall always terminates a 10-day cycle). The LCD display
on the Control will indicate the number of the zone in which the event
occurred (e.g., 01, 02, etc,), accompanied by the appearance of the word
CHECK (trouble), ALARM and, if applicable, FIRE, to describe the type
of event that occurred in the displayed zone. If more than one event had
occurred, the events wtll be displayed in zone sequence Each dtsplay
will appear for 1-2 seconds, then disappear.
When all information has been displayed and noted, the recall mode is
exited by entering:
Security Code plus OFF
At this point, ail exsting memory is erased and the alarm memory is
reset. The 10-day cycle will start again only when the next event occurs.