Installer options are stored in non-removable, electrically erasable, non-
volatile EEPROM memory. These options must be programmed for the
particular installation to establish its specific alarm and reporting
feat ures.
The security control may be programmed from its own keypad (the most
convenient method) or from an optional 4137 or 4157 remote console, or
can be programmed locally from the 699 Programmer. Information
regarding the Programmer is included with the No. 695-30XT Program-
ming Cartridge.
The system is factory-programmed to a set of preset values, which can
be altered by the Installer to suit the specific needs of a parhcular instal-
lation or installation company. The preset values are detatled (n the Fac-
tory Programming Table.
Nottz Programming mformatlon E stored In non-volatlle EEPROM
memory in this Control (removal of power WIII
not result in the loss
of the information). Consequently, it is possible to program the
Control at any time – even at the installer’s premises prior to the
actual installation. Simply apply DC power temporarily to the Con-
trol and then program the unit as desired.
When programming from the Control, note the following”
1, Enter the Programming mode by simultaneously depressing the * and
# keys within 30 seconds after power is applied to the Control, or sub-
sequently by keying the code 4 +
1 +3 + O followed by depression of
CODE + O + O keys. Once an Installer code is programmed, use it
instead of 4130 (as 4130 is no longer present) to gain access to the
programming mode.
2
3
4
When a data tleld has been completely programmed, the Control WIII
“beep” three times and then automatically proceed to, and display, the
next data field address to be programmed.
If the number of dlglts that yob enter In the data field IS less than the
maximum permitted (for example, phone number), then the Control wit
display the last data entered. To proceed, the next data field address
to be programmed must then be entered (for example, *OS).
If an address is lm~ro~erly entered, the Control will discday FC. If a
program entry IS rnprope~ly entered (for example, a larger number
than that which is permitted), the Control display WIII go blank. In
either case, simply re-enter the number.
The followlng ISa description of commands necessary for programming,
FUNCTION
PROCEDURE
ENTER PROGRAM- 1. POWER UP, then depress *and #simultane-
MING MODE:
ouslywithln 30 seconds of powering up.
OR
2 Initially,
Key:4+l +3+ OPIUSCODE key+O+O.
OR
3 After Installer Code
IS programmed, key”
Installer Code + CODE key + O + O.
Notes: User #l (Installer) must be enabled (in
Address 52) if Type 3 method of entry Isto
be used.
Type 3 method of re-entry to the pro-
gramming mode is inhibited if the pro-
gramming mode E,exited vla use of *98
Type 1 method of entry can always
be used unless console programming
has been locked out by the remote
downloader.